The reason for the excess sodium ion in the superheated steam of waste heat boiler
The reason for the excess sodium ion in the superheated steam of waste heat boiler is due to the leakage of the evaporating tube. When the boiler is in operation, the high-temperature flue gas passes through the evaporating tube to heat the feed water, and the sodium ions in the feed water are deposited on the surface of the evaporating tube. If there is a leakage in the evaporating tube, the flue gas will enter the feed water system through the leakage, which will increase the sodium ion content in the feed water and cause the sodium ion content in the superheated steam to exceed the standard.
It appears that one possible cause of the over-limit sodium ion in the superheated steam of the waste heat boiler could be due to the leakage of the thermal oil. This leakage can cause the oil to mix with the feed water and eventually enter the steam system, resulting in high levels of sodium ions in the superheated steam. This can be a serious issue as high levels of sodium ions can cause corrosion and damage to the turbine blades and other equipment downstream.
To address this issue, it is recommended to properly maintain the waste heat boiler and ensure that there are no leaks in the system. Regular monitoring of the feed water and steam quality can also help identify any potential issues early on. Additionally, it may be necessary to install a water treatment system to remove impurities and prevent corrosion.
As for ZOZEN Boiler, they have extensive experience in the design and manufacturing of waste heat boilers, and can provide customized solutions to meet the specific needs of customers. Their manufacturing process utilizes advanced technology and high-quality materials to ensure the reliability and efficiency of their boilers.
-
WNS series gas-fired (oil-fired) skid-mounted hot water boilerLive Chat0.7-2.8 MW1.0 MPa
-
DZW series biomass-fired reciprocating grate steam boilerLive Chat15-35 t/h1.25 MPa / 1.6 MPa / 2.5 MPa
-
DZL series biomass-fired steam boilerLive Chat2-10 t/h1-2.5 MPa
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat

-
Packaging connects production with consumption. A carton, a piece of corrugated board, or a roll of plastic film may look light and simple, but behind each of them is a stable, continuous, and process-matched thermal energy system. As demand continues to grow in food packaging, industrial packaging, e-commerce packaging, and plastic packaging, the packaging industry is placing more specific requirements on boiler equipment: stable steam supply, fuel adaptability, process temperature control, ope...26 May 2026 -
When an industrial boiler arrives on site, what first catches a customer’s attention is often not the specification sheet, but the overall appearance of the equipment in the plant environment. For boiler equipment, exterior design is not only about visual presentation; it also reflects the manufacturer’s approach to product details, on-site management, and brand image. ZOZEN Boiler has upgraded the exterior of its SZL series biomass boiler, presenting a more unified visual design and...19 May 2026 -
From May 6 to 7, 2026, PALMEX JAKARTA 2026, the International Palm Oil Industry Equipment Exhibition, was held at JIEXPO in Jakarta, Indonesia. At booths 190 & 192, ZOZEN Boiler presented its boiler products and thermal energy solutions for industries such as palm oil processing. During the two-day exhibition, ZOZEN welcomed multiple groups of visitors, including existing clients and new prospects. Some new visitors returned to the booth several times for further discussions, and the overall...12 May 2026