A project requiring both a 10 t/h biomass steam boiler and an 1800 kW biomass thermal oil heater needs two different heat-transfer systems. The steam boiler supplies saturated or superheated steam for process use, while the thermal oil heater supplies high-temperature thermal oil through a closed circulation loop. ZOZEN can prepare the two systems as separate units with coordinated technical documents, auxiliary equipment lists, and delivery information.

For the steam requirement, a DZL series biomass steam boiler can be considered. The DZL series has a capacity range of 2–10 t/h and a working pressure range of 1–2.5 MPa. For a required capacity of 10 t/h, the selected boiler would be designed around the specified working pressure, steam temperature, feedwater conditions, and biomass fuel. The DZL boiler can burn fuels such as biomass pellets, straw, wood blocks, palm kernel shell, rice husk, corn cob, and waste wood, provided that the feeding and combustion system are matched to the fuel characteristics.

For the 1800 kW thermal oil requirement, a YLW series biomass-fired horizontal thermal oil heater can be evaluated. The YLW biomass thermal oil heater has a capacity range of 2,800–29,200 kW according to the available product information, so an 1800 kW requirement falls below that stated range. The technical team should therefore review whether the customer’s 1800 kW refers to the required heat output, fuel input, or another design value. A suitable model and configuration should only be confirmed after this point is clarified.

The thermal oil heater system normally includes the heater body, thermal oil circulating pump, expansion tank, storage tank, oil filter, fuel-feeding system, combustion air fans, induced-draft fan, dust collector, chimney, control cabinet, safety accessories, and thermal oil. The steam boiler system may include the boiler, burner or biomass combustion system, feedwater pump, water treatment system, economizer, dust collector, chimney, control cabinet, and blowdown equipment.

Using two biomass heat sources may allow one fuel storage and handling concept to serve both systems, but this depends on the boiler-room layout and operating schedules. The fuel type, moisture content, particle size, ash content, daily consumption, and storage period should be assessed before the feeding system is designed. The two units may also require separate combustion control strategies because their heat-transfer media and operating temperatures are different.

The quotation package should include technical specifications, product drawings, fuel requirements, auxiliary equipment, control functions, foundation loads, installation scope, spare parts, packing method, delivery terms, and commissioning support. Product pictures and operation videos can be supplied as part of the technical communication package, subject to product availability.

ZOZEN has experience in manufacturing biomass steam boilers and thermal oil heaters for industrial applications. The company can coordinate both equipment lines through one project team and provide design support for the boiler room, fuel system, flue-gas system, control system, installation, and commissioning. For this project, the 10 t/h biomass steam boiler can be developed within the DZL capacity range, while the 1800 kW thermal oil heater capacity requires technical confirmation before a final model and price are issued.

Related FAQs View More
Related news View More
  • Heating Solutions, Local Support: ZOZEN Boiler’s Approach to Expanding in Vietnam
    Industrial heating upgrades can have a direct impact on a factory’s production schedule and operational stability. For manufacturers investing in new facilities or upgrading equipment in Vietnam, boiler selection involves more than fuel costs. Process temperatures, continuous heat supply, emission requirements, and long-term maintenance must all be taken into account. Whether transitioning from coal to natural gas or biomass, manufacturers need a heating solution tailored to their actual p...
    17 Nov 2026
  • Energy Costs and Stable Steam Supply Draw Attention as ZOZEN Boiler Provides Diverse Steam Solutions for Textile Enterprises Worldwide
    From spinning and weaving to dyeing, printing and heat setting, steam is required throughout multiple stages of textile production. As textile enterprises pay closer attention to energy costs, steam supply stability and emission requirements, boiler selection can no longer be based solely on rated evaporation capacity. Local fuel availability, production load, boiler room conditions and ongoing operation and maintenance also need to be considered. Recent textile projects served by ZOZEN Boiler ...
    10 Nov 2026
  • ZOZEN Boiler Supports Building Materials Projects in Hubei with Steam and Thermal Oil Solutions
    IntroductionIn Wuhan, Hubei Province, Hubei Hanjia New Materials Co., Ltd. and Wuhan Yiqingsheng Building Materials Co., Ltd. required thermal energy equipment for autoclave curing and continuous production-line heating, respectively. Based on the production processes, fuel conditions and site requirements of the two companies, ZOZEN Boiler supplied an 8 t/h DZL series biomass steam boiler and a 7.2-million-kcal YWW series biomass thermal oil boiler. The two projects use different heat-transfer ...
    03 Nov 2026

Find the Right Boiler For You

Name *

Email *

WhatsApp/WeChat

Products

Power/Capacity