Why gas-fired boiler chimney drops water?
If you notice water dripping from a gas-fired boiler's chimney, it could be due to condensation, which is a common issue in high-efficiency boilers. Here are some key reasons and explanations for this phenomenon:
Condensation of Flue Gases: Modern high-efficiency gas boilers are designed to extract as much heat as possible from the combustion gases before they are expelled through the chimney. This process can cool the gases to a point where the moisture in them condenses into water. This is more common with boilers having a high-efficiency rating (typically condensing boilers) because they cool the flue gases below the dew point.
Inadequate Flue Gas Temperature: If the flue gas cools too much before exiting the chimney, it can cause condensation. This might happen if the boiler is oversized for the heating requirement, causing it to run short cycles and not allowing the flue gas to heat sufficiently.
Poor Chimney Design or Insulation: An improperly designed or insulated chimney can cool the gases too quickly, leading to condensation. The flue should be properly sized and insulated to ensure the gases remain hot enough until they are expelled.
Humid Climate Conditions: In areas with high humidity, the moisture content in the air can contribute to more condensation in the chimney.
Blockages or Leaks: Any blockage in the flue or leaks can cause the hot gases to cool down more rapidly than intended, leading to condensation.
Condensate Drain Issues: If the boiler is a condensing type, it will have a condensate drain to remove the water. If this drain is blocked or malfunctioning, it can cause water to back up and potentially leak out of the chimney.
Short Chimney Height: A chimney that is too short can cause the flue gases to cool down rapidly, leading to condensation.
It's important to address this issue because prolonged condensation can lead to corrosion of the chimney, boiler components, and can negatively impact the boiler's efficiency. It’s advisable to consult with a heating professional to diagnose the specific cause and rectify the issue. They may recommend solutions such as adjusting the boiler settings, insulating the chimney, or repairing the condensate drain system.
-
SZS series gas-fired (oil-fired) steam boilerLive Chat2-110 t/h1.25-5.3 MPa
-
WNS series gas-fired (oil-fired) steam boilerLive Chat1-20 t/h0.7-2 MPa
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat
-
Recently, PT PAKAN SEHAT UNGGUL, a prominent company in Indonesia's feed industry, selected ZOZEN Boiler's SZL series biomass steam boiler to provide efficient power for its production lines. This decision was based not only on ZOZEN Boiler's strong reputation in the Indonesian market but also on its expertise in the biomass energy sector. Biomass Steam Boilers: A Key Role in Feed Production Biomass steam boilers play a critical role in feed production by providing a stable supply of h...18 Feb 2025
-
In the context of green transformation within the fine chemical industry, the stability and precision of thermal energy supply have become pivotal for both production efficiency and environmental performance. Anhui Rongtai New Materials Co., Ltd., with its annual production capacity of 100,000 tons of resin series, 85,000 tons of coating series, 20,000 tons of water-based UV electronic specialty materials, and 15,000 tons of water-based dispersion series products, has opted for ZOZEN Boiler&rsqu...11 Feb 2025
-
On February 6, 2025, Wuxi ZOZEN Boiler Co., Ltd. held its 2025 Annual Sales Conference with the theme of "Riding Against the Tide - Innovation and Change in the Era of Cut - throat Competition", as well as the 2024 Advanced Sales Commendation Ceremony. General Manager Zhang Guoping, middle - level managers, and sales elites gathered together to review the achievements of the past year and plan the development blueprint for the new year. Through experience sharing, strategic deployment, and comme...07 Feb 2025