  • ZOZEN Boiler-busy workshop of SZS series boiler 2020-12-15
    ZOZEN SZS series oil-fired/gas-fired boiler proper adopts the D-type structure. One side is the furnace, and the other side is the convection heating surface. The partition walls around the furnace body, the partition wall between furnace and convection section, and the front and rear walls all adopt the membrane wall structure. There are foreign advanced burner, economizer and condenser installed at the end of flue gas duct, which can lower the exhaust gas temperature to 60℃, achieve the thermal efficiency of over 98% and control the emission of NOx to less than 30mg/Nm3. This kind of boiler has the characteristics of energy saving and environmental protection, safety and efficiency, simple operation and maintenance, and fully automatic control system which can realize unattended operation.
  • ZOZEN 3 stes of SZS series gas-fired steam boilers shipped to Bolivia 2020-01-17
    Bolivia is the highest average altitude country in the world, local Bolivian companies have higher requirements for boilers than general boilers. As the altitude increases, the atmospheric pressure and the air density decrease accordingly, which adversely affects boiler combustion. In view of this situation, ZOZEN technical team makes adjustments from the combustion system and exhaust system of boiler, fully considering the influence of low air pressure on boiler body design and combustion. By appropriately increasing the volume of the furnace to extend the residence time of the fuel in the furnace, and the problems of slow fuel burning speed and long burning time are solved.
  • SZS series gas fired (oil fired) water tube boiler 2019-11-04
    SZS series boiler is designed with longitudinal double drums and " D " type chamber structure. The furnace is on the right and convection tube bank is on the left. The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways. Around the furnace is membrane wall. Furnace and tube bundle are totally separated by the membrane wall at the left side of the furnace. The back part of convection tube bank is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, convection tube bank area, and then from left front part enters spiral fin coil economizer and condenser, and finally is discharged to atmosphere through chimney.