Steam boilers use a contained heat system to generate steam. The steam travels through pipes in the building’s walls where they emerge at radiators in heating systems. The radiators warm from the steam’s heat. As the steam gives off its heat, it condenses back to liquid water and returns to the tank. A boiler system of this type that does not allow outside water sources is a closed system and is highly efficient for using all the condensed water. An open network may be required in operations where the steam or water gets contaminated in such a way that it cannot return to the boiler for reuse.
Low-pressure boilers operate at a lower pressure and reach lower temperatures than high-pressure steam boilers. Water in low-pressure boilers is not heated beyond 250ºF, and the steam pressure does not exceed 15 psi (pounds per square inch).
A condensing boiler can condense the water vapour in the flue gases and withstand the corrosive and acidic qualities of the flue gas condensate. Although most boilers can condense the flue gasses, only boilers that have heat exchangers constructed from materials able to withstand the corrosion should be used in condensing application. Condensing boilers with primary and secondary heat exchanger do not work well as they are not able to fully condense and defeat the purpose of using a condensing boiler. Also, boilers with this arrangement are prone to condensation in the primary heat exchanger at lower firing rate which can cause damage to the heat exchanger.
Nox is the generic term for a group of highly reactive gases, all of which contain nitrogen and oxygen in varying amounts. Many of the nitrogen oxides are colorless and odorless. However, one common pollutant, nitrogen dioxide (NO2) along with particles in the air can often be seen as a reddish-brown layer over many urban areas.
Nox forms when fuel is burned at high temperatures, as in a combustion process. The primary sources of Nox are motor vehicles, electric utilities, and other industrial,...
In the operation of gas-fired steam/hot water boiler, it need continuous water supply to ensure the water volume in the drum. Once water shortage occurs, it will cause the boiler dry burning problem, which will further result in the boiler failure and other problems.
The high heat transfer of the boiler requires good medium. With the improvement of boiler in the production technology and intelligenlization, gas-fired boilers have more strict requirements for boiler operation medium in order to improve the boiler operating performance, reduce boiler failures and costs.
Gas-fired industrial boilers are high-efficiency, eco-friendly and energy-saving, and they play an important role in the production-oriented enterprises. Due to strict requirements for pollutant emissions, enterprises often attach great importance to the emission performance of boilers.