If the hot oil pump of the fully automatic thermal oil heater is suddenly damaged and stops working during the operation, the boiler circulation will be blocked. If the fuel is still burning to make the oil temperature keep rising, it will cause the coking of the hot medium oil which is easy to cause a fire. If the fully automatic thermal oil heater catches fire due to the power cut during the operation, the boiler operator should quickly put out the fire in the furnace to stop the fuel from burning, and blow a large amount of cold air into the furnace to lower the temperature.
The flue gas first enters the cyclone dust collector which acts as a primary dust collector to make the large dust particles in the flue gas settle down. The cyclone dust collector is a dust removal device which uses the centrifugal force generated by the cyclone flow to separate the dust particles from the air flow. Afterwards, the flue gas enters the wet scrubber dust collector which is a circular-type cylinder. The circulating water enters the dust collector from the upper overflow tank to form a uniform water film on the inner wall of the dust collector. The flue gas is induced tangentially or spirally from the lower part of the cylinder and rotates in the cylinder. Under the influence of the centrifugal force, the dust particles are separated from the flue gas and then the flue gas is also spirally led out from the top of the cylinder. The dust particles are thrown to the water film, transferred to the bottom and finally discharged from the dust port.
In the operation of gas-fired steam/hot water boiler, it need continuous water supply to ensure the water volume in the drum. Once water shortage occurs, it will cause the boiler dry burning problem, which will further result in the boiler failure and other problems.
Boiler is a piece of equipment with large energy consumption. Therefore, both boiler manufacturers and purchasers regard energy conservation as an important indicator of boiler performance. The daily energy-saving measures of the natural gas fired boiler are mainly as follows.
The vertical type and horizontal type are the two main types of boiler. The vertical gas-fired boiler has small volume and is suitable for small workshops or small production enterprises. It is often used in the fields of hot water and heating. The horizontal gas-fired boiler has larger volume with a wider application range than the vertical gas-fired boiler.
The high heat transfer of the boiler requires good medium. With the improvement of boiler in the production technology and intelligenlization, gas-fired boilers have more strict requirements for boiler operation medium in order to improve the boiler operating performance, reduce boiler failures and costs.