  • What reasons cause the increase of burner noise of a gas-fired boiler? 2020-02-21
    1. If the stop valve of the oil circuit is closed or the feeding of oil is insufficient and the oil filter is blocked, it is necessary to check that the valve in the oil circuit is open, the oil filter works normally and clean the filter screen of the pump. 2. If the oil temperature is low, viscosity is too high or the temperature of the oil fed by pump is too high, the oil temperature needs to be increased or decreased. 3. If the the domestic sewage treatment equipment oil pump breaks down, the oil pump is required to be replaced. 4. If the bearing of fan motor is damaged, it is necessary to replace the motor or bearing. 5. If the fan impeller is too dirty, it is required to be cleaned.
  • What is the standard gas consumption of 10 tph gas-fired steam boiler? 2020-02-21
    The gas consumption of 10 tph gas-fired boiler is related to technical parameters. Such as heating surface layout, heat preservation effect, heat loss, water capacity, etc. The calculation formula of gas consumption of 10 tph gas-fired boiler is as follows: =10 tph gas-fired boiler output÷ thermal efficiency ÷calorific value of natural gas = 6,000,000 kcal ÷ 0.98 ÷ 8,600 kcal / h = 712 m3 Therefore, the gas consumption of 10 tph gas-fired boiler is 712 m3/ h The gas consumption of the above gas-fired boiler is calculated at full capacity. In practice, the gas consumption changes with the operation load and operation conditions. In addition, if thermal efficiency of the gas-fired boiler is different, the gas consumption is different, too. The higher thermal efficiency is, the lower gas consumption is.
  • What is the function of the burner of the industrial boiler? 2020-02-21
    The function of the burner is to send the fuel and air into the furnace constantly, organize the air flow of pulverized coal reasonably and mix them well for rapid and stable ignition and combustion.
  • Why should oil be atomized prior to the oil combustion of oil-fired boilers? 2020-02-21
    The oil and air must be mixed for the combustion of the fuel droplets to take place. The combustion speed depends on the evaporation speed of oil droplets and the mixing speed of oil and air. The evaporation speed of oil droplets is related to the diameter and temperature of oil droplets. The smaller the fuel droplets, the higher the temperature and the faster the evaporation. On the other hand, it is conducive to mixing and combustion. The smaller the fuel droplets, the larger the air contract surface. Therefore, the fuel oil must be atomized before combustion. And, the oil can be heated and evaporated rapidly and fully burnt after it is injected to the furnace.
  • What is the advantages of a biomass-fired boiler? 2020-02-13
    Firstly, the combustion of biomass fuel is easy to control. The fuel is easy to ignite. Besides, the combustion speed is faster than that of coal. Secondly, the biomass-fired boiler can be ignited and extinguished at any time while the coal-fired boiler cannot. The biomass-fired boiler can also be ignited automatically. Thirdly, the biomass-fired boiler can achieve zero emission of sulfur dioxide, which belongs to environment-friendly boilers.
  • What is the material used in the impulse bag filter of biomass-fired boiler? 2020-02-13
    The temperature of flue gas generated by a biomass-fired boiler is relatively high. But it is not corrosive. So, it is suitable to use heat resisting glass fiber needled felt bag which has a good use effect. Moreover, this kind of cloth bag is not very expensive.
  • What are the characteristics of the pellet fuel used in biomass-fired boilers? 2020-02-13
    1. The fuel volume is 1 / 30 ~ 40 of the raw material volume after molding; 2. The specific gravity is 10-15 times of the raw material, and the moisture content is between 12% and 18% (the moisture content of coal is below 10-15); 3. The net calorific value can reach 3500-4500 kcal (the net calorific value of class II bituminous coal is 3700-4700 kcal / kg); 4. The ash content is less than 10% (the ash content of coal is more than 20%); 5. Volatile matter ≥ 65.62% (volatile matter of class II bituminous coal≥20%). 6. Biomass fuel belongs to renewable clean energy, which is the same as wind energy and solar energy. The biomass fuel is rich in resources, it can ensure the sustainable use of energy. 7. The sulfur content and nitrogen content of biomass fuel are low, the amount of SOx and NOx generated in the combustion process is low.
  • How to choose the dust collector for coal-fired boilers? 2020-02-07
    The selection of dust collector for coal-fired boilers is determined by the purpose and requirements of dust collecting. If the requirement is just dust collecting, the impulse bag filter is a good choice, the efficiency can reach up to 99%. If both dust collecting and desulfurization are required, you should choose bag filter plus spray desulfurization. Bag filter plus double alkali desulfurization is suggested for higher requirements.