Thermic fluid heater boilers are widely used in a variety of industries because of their excellent performance and energy efficiency. They offer several benefits over traditional steam boilers, including better temperature control, easy operation, and low maintenance costs. Here are some frequently asked questions about thermic fluid heater boilers:
1, What is a thermic fluid heater boiler?
A thermic fluid heater boiler is a device that uses thermal oil or heat transfer oil to transfer heat fr...
The coal-fired boiler uses coal as fuel. The consumption of coal is a key factor to measure the efficiency of boilers. Under the same condition, the coal-fired boiler with less coal consumption can save more costs for enterprises. However, the coal consumption of coal-fired boilers is related to many factors, such as the efficiency of the boiler, the calorific value of fuel coal and the degree of coal combustion.
An Interlock in the boiler’s control system is a programmed or hardwired condition that forces a device to be in a pre-determined or permissive state before the process can continue.
Depending on design pressure, fuel type, either liquid, gas or solid, all steam boiler require interlocks to sequence the operation and to prevent damage to the boiler. Examples of such devices are High or Low Boiler Drum Water Level, Low Boiler Feed Pump Pressure, High or Low Fuel pressure, High or Low Atomization pressure (oil fired), Proof of Ignition, Proof of Flame, FD and/or ID (solid fuel) Fan Motor Operation or combustion air pressure, Damper or Valve position and High Boiler Steam Pressure as well as O2 and furnace temperature.
Modular gas-fired boiler, according to the user's load and design needs, combines several independently operating module units into an integral boiler. By monitoring and calculating the changes of indoor and outdoor temperature and temperature of supply and return water, the computer automatic control system can control each level of modules, automatically adjust the number of modules to start and stop, make the output heat always match the actual required heat load, and ensure that each module ...
Different steam pressures correspond to different steam temperatures.
1. The steam temperature of low-pressure boiler is mostly saturation temperature or not higher than 400℃.
2. The outlet pressure of medium-pressure boiler is 3.8 ~ 5.4 MPa, and the commonly used steam temperature is 450℃.
3. The outlet pressure of sub-high pressure boiler is 5.4 ~ 9.8 MPa, and the common steam temperature is 540℃.
It is necessary to confirm whether the boiler pressure is correspondingly higher when steam is not used and lower when steam is used. This is mainly due to the different water pressure and volume under different pressures.
The limited space refers to a space which is closed or partially closed, relatively isolated from the outside world, with narrow entrances and exits, staff can't work in it for a long time, natural ventilation is poor, and toxic, harmful, inflammable and explosive substances or oxygen content is easy to accumulate. To define a limited space, it is necessary to meet the following three conditions at the same time, which are indispensable: the volume is large enough for people to enter completely; Or restrict the entry and exit; It's not designed to stay for a long time.
As a kind of equipment that needs to be used continuously for a long time, it is quite common for the boiler to malfunction due to operation errors or environmental quality problems. Today, Let’s discuss the causes, analysis and solutions of common faults of steam boilers.