  • How to calculate the gas consumption in a boiler? 2019-07-19
    The boiler gas consumption calculation need the following parameters: gas calorific value and boiler thermal efficiency. Theoretically, the gas consumption of boiler = boiler thermal capacity ÷ (calorific value of gas x boiler thermal efficiency ) Take the 1 tph steam boiler as an example: = 600,000 cal / (8500Kcal * 0.98) =72m3/h, the 1 tph boiler's gas consumption per hour is about 72 cubic meters.
  • What is a fire tube steam boiler? 2019-07-05
    A fire tube steam boiler is a boiler where the combustion gases from the burner are channeled through tubes that are surrounded by the fluid to be heated. The boiler body is the pressure vessel and contains the fluid. In most cases, this fluid is water that will circulate for heating purposes or become steam for use in processing. Each set of tubes through which the combustion gas passes, before making a turn, is considered a "step". Consequently, a three-step boiler will have three sets of pipes with the outlet located at the rear of the boiler.
  • How does a fire tube boiler start up when cold? 2019-06-28
    The action of starting up a fire tube boiler for the first time is already a cold start. As a result, the mechanical load in this type of boiler is much greater, as the main characteristic of cold starts is the absence of boiling water and greater stress on the connection and anchorage elements of the boiler. To make this start a bit easier for the boiler, the boiler operator should reduce the burner load to a boiling point.
  • What is a fire tube boiler? 2019-05-31
    Any boiler where the products of combustion flow on the inside of a tube with the heat transfer media (ex. water, steam, or hot oil) on the outside. The tubes can be orientated vertically, horizontally or at an angle.
  • What's the difference between WNS series gas-fired (oil-fired) boilers and SZS series gas-fired (oil-fired) boilers? 2019-02-12
    1. In terms of boiler body structure, WNS series gas-fired (oil-fired) boilers are fire tube boilers; SZS series gas-fired (oil-fired) boilers are water tube boilers; 2. In terms of boiler working pressure, if the boiler pressure is below 1.6Mpa, the choice is usually the WNS series gas-fired (oil-fired) boiler, if the boiler pressure is above 1.6Mpa, the SZS series gas-fired (oil-fired) boiler may be a better solution.  Some high-pressure boilers also adopted SZS series gas-fired (oil-fir...