zozen boiler
HomeBoiler tagsgas boiler efficiency

“gas boiler efficiency”- related faq

  • What is a thermal fluid system? 2019-04-19
    A thermal fluid system is a closed loop using mineral or synthetic oil as the heat transfer fluid. These systems operate at elevated temperatures while maintaining low system pressures. Fluid is circulated within the heater tubes and flue gases heat the fluid.
  • What are the main components of circulating fluidized bed boiler? 2019-03-21
    1. Primary air fan: after being heated by the air pre-heater, primary air enters into the wind chamber, then into the furnace through wind caps through the air distributor to fluidize particulate materials;2. Secondary air fan: after being heated by the air pre-heater, secondary air enters into the furnace through the secondary air ducts for complete combustion of fuels; the seal air, conveying air and fuel spreading air of the feeding device also adopt secondary air; 3. Circ...
  • What conditions are required for the full combustion of biomass-fired boiler fuel on the chain grate? 2019-03-21
    1. Rational air distribution, supply sufficient and rational air by region; 2. Appropriate furnace temperature;3. Suitable air turbulence and mixing in furnace;4. Fuels remain long enough on chain grate and in the furnace;5. Keep a reasonable distance between the fuel hopper and the flame fronts to avoid igniting fuels in the hopper.The biomass-fired boilers are optimally designed according to the characteristics of different biomass fuels. ZOZEN will customize the biomass-fired boiler for ...
  • What's the difference between WNS series gas-fired (oil-fired) boilers and SZS series gas-fired (oil-fired) boilers? 2019-02-12
    1. In terms of boiler body structure, WNS series gas-fired (oil-fired) boilers are fire tube boilers; SZS series gas-fired (oil-fired) boilers are water tube boilers; 2. In terms of boiler working pressure, if the boiler pressure is below 1.6Mpa, the choice is usually the WNS series gas-fired (oil-fired) boiler, if the boiler pressure is above 1.6Mpa, the SZS series gas-fired (oil-fired) boiler may be a better solution.  Some high-pressure boilers also adopted SZS series gas-fired (oil-fir...
  • What are the phenomena of coking on the circulating fluidized bed boilers? 2018-11-23
    The bed temperature rises sharply. Oxygen levels go down and sometimes drop to zero. The electric current of primary air fan is less and wind pressure of air compartment is higher. Negative pressure of furnace is increased while the electric current of induced draft fan is reduced. The slag discharge is difficult or unsuccessful. When appearing bed clinkering, the bed temperature and bed pressure will be uneven distributed and not at normal condition; the measuring point of part bed tempe...
  • What function do thermal oil heaters have in kinds of industry? 2018-08-30
    Chemical industry: polymerization, condensation, distillation, rectification, concentration, evaporation, and melting.Petrochemical: synthesis, reaction, distillation, rectification, heating, heat preservation, storage tank heating, heavy oil heating.Oil grease: oil decomposition, deodorization, fatty acid distillation, heating, hydrogenation reaction, esterification.Plastic rubber: hot pressing, calendering, extrusion, vulcanization molding.Leather industry: artificial leather processing.Textile printing and dyeing: heat setting, drying, baking, evaporation, melting.Chemical fiber: polymerization, melt spinning, weaving machine processing, molding, thermosetting, stretching, drying.Paint: paint baking, drying, high temperature solid melting, home appliances, vehicle baking paint, painting.Automotive aircraft: painted baking, drying, thermoforming, high temperature bonding.Wood processing: hot pressing, drying, wood processing and wood products (materials, furniture), wood-based panels
  • What if liquid level gauge alarms for low liquid level of expansion? 2018-07-12
    Specific performance:Low level alarm of expansion tank.Answer:Cause of failure:The pipeline system (including heater) has not been replenished in time after oil leakage or degassing. Troubleshooting:Eliminate system defects and add oil.