Home Service FAQs FAQ of circulating fluidized bed boilers How to solve the problem of coking in circulating fluidized bed boiler operation?

How to solve the problem of coking in circulating fluidized bed boiler operation?

12 Jul 2018

(Question Details) Specific Performance:

(1) The bed temperature has risen sharply.

(2) The oxygen level drops even to zero.

(3) The current of the primary blower is reduced, and the wind pressure in the wind chamber is high and fluctuates.

(4) The furnace negative pressure increases and the induced draft fan current decreases.

(5) Difficulties in slagging.

(6) If coking in low temperature, the bed temperature, bed pressure distribution is uneven, the deviation is too large, the bed pressure, the plenum pressure, the bed temperature is not normal, and the local bed temperature measurement point is not normally raised or lowered.

(7) The bed pressure indicator value fluctuates little.

 

Answer: causes of failure :

(1) Improper operation, resulting in overheated bed temperature and coking.

(2) The primary air volume during operation is kept too small, which is lower than the minimum fluidized air volume, so that the material can’t be well fluidized but piled up, the temperature field of the entire furnace is changed, the burning share of the suspension stage is decreased, and the boiler output is reduced, if increase the amount of coal blindly at this time, it will inevitably cause overheating and coking.

(3) Bad fluidization caused by damaged hood.

(4) Recycling device blocking the ash and causing cycle interruption.

(5) The material pressure difference is too high.

 

Troubleshooting:

(1) Strengthen the combustion adjustment and increase the fluidization speed. If the material pressure difference is too high, the slag should be strengthened.

(2) If the bed temperature is too high, the coal supply will be reduced to zero,open the door with high negative pressure of the furnace, and remove the focal block with a hook.

(3) If the coking of furnace is serious, we should stop the operation of boiler.


Related FAQs View More
Related news View More
  • Building a Plywood Plant in Africa: How to Choose the Right Heat Source?
    For many manufacturers with mature production experience in China, expanding capacity overseas or building a new factory abroad often starts with one key question: can the local infrastructure and energy supply support long-term operation? This is especially important in Africa. In many countries, raw materials such as timber are readily available, while conventional fuels like natural gas and diesel are often more expensive and less stable in supply. For plywood plants, this creates a practica...
    24 Mar 2026
  • Global Carbon Challenge: ZOZEN Industrial Boilers Drive Green Transition
    From late 2025 to early 2026, forward-looking reports from the World Economic Forum (WEF) and other organizations indicated that despite significant growth in global renewable energy capacity in 2024, global carbon dioxide emissions still reached historical highs. Facing severe climate safety challenges, multiple countries globally have introduced stricter environmental policies to promote a green and low-carbon economic transition. In this macro context, energy conservation and emission reducti...
    17 Mar 2026
  • Green Industrial Transformation in Inner Mongolia: Multiple Gas Boilers from ZOZEN Boiler Support Local Manufacturing
    The vast land of Inner Mongolia is undergoing a profound green industrial transformation. From fine chemical parks in Wuhai to food processing bases in Hohhot, traditional high-energy-consumption production models are gradually shifting toward cleaner and lower-carbon operations. In this wave of industrial upgrading, Wuxi Zozen Boilers Co., Ltd. (hereinafter referred to as “ZOZEN Boiler”), a manufacturer with over 30 years of experience in industrial thermal equipment, has delivered ...
    10 Mar 2026

Find the Right Boiler For You

Name *

Email *

WhatsApp/WeChat

Products

Power/Capacity