Home Service FAQs FAQ of circulating fluidized bed boilers How to solve the problem of coking in circulating fluidized bed boiler operation?

How to solve the problem of coking in circulating fluidized bed boiler operation?

12 Jul 2018

(Question Details) Specific Performance:

(1) The bed temperature has risen sharply.

(2) The oxygen level drops even to zero.

(3) The current of the primary blower is reduced, and the wind pressure in the wind chamber is high and fluctuates.

(4) The furnace negative pressure increases and the induced draft fan current decreases.

(5) Difficulties in slagging.

(6) If coking in low temperature, the bed temperature, bed pressure distribution is uneven, the deviation is too large, the bed pressure, the plenum pressure, the bed temperature is not normal, and the local bed temperature measurement point is not normally raised or lowered.

(7) The bed pressure indicator value fluctuates little.

 

Answer: causes of failure :

(1) Improper operation, resulting in overheated bed temperature and coking.

(2) The primary air volume during operation is kept too small, which is lower than the minimum fluidized air volume, so that the material can’t be well fluidized but piled up, the temperature field of the entire furnace is changed, the burning share of the suspension stage is decreased, and the boiler output is reduced, if increase the amount of coal blindly at this time, it will inevitably cause overheating and coking.

(3) Bad fluidization caused by damaged hood.

(4) Recycling device blocking the ash and causing cycle interruption.

(5) The material pressure difference is too high.

 

Troubleshooting:

(1) Strengthen the combustion adjustment and increase the fluidization speed. If the material pressure difference is too high, the slag should be strengthened.

(2) If the bed temperature is too high, the coal supply will be reduced to zero,open the door with high negative pressure of the furnace, and remove the focal block with a hook.

(3) If the coking of furnace is serious, we should stop the operation of boiler.


Related FAQs View More
Related news View More
  • A Long-Run Story of an Old Boiler: ZOZEN WNS Series Gas-Fired Boiler Operating for 16 Years
    At the production site of a pharmaceutical company in Shanghai, a ZOZEN gas-fired steam boiler commissioned in 2010 has been operating steadily for 16 years. For this established pharmaceutical company, founded in 1995, the steam system is closely related to production rhythm, process coordination, and on-site operation support. Whether the equipment can maintain stable operation over the long term directly affects the continuity of daily production. Time is a practical test, and the continuous ...
    07 Jul 2026
  • A Boiler Generating Steam for Brewed Aroma: ZOZEN Boiler Supports Green Production at Yanjing Beer
    As the beer industry moves toward greener, more continuous, and more refined production, the steam system has become an important part of brewing operations. Recently, the cooperation case between ZOZEN Boiler and Yanjing Beer (Guilin Liquan) Co., Ltd. once again highlighted the essential role and system value of industrial boiler equipment in the food and beverage industry. Industrial Heat and Beer Brewing Are Closely Connected From a Drop of Beer, the Value of Stable Steam Becomes ClearYan...
    24 Jun 2026
  • ZOZEN Skid-Mounted Boiler Exported to Thailand Supporting a Stationery Manufacturer
    Recently, ZOZEN Boiler delivered a 3-ton WNS series skid-mounted steam boiler to a stationery products manufacturer in Thailand. The customer mainly produces solid glue, crayons, oil pastels and other stationery products. During production, the customer has clear requirements for continuous and stable steam supply. Based on the customer’s process features and site conditions, ZOZEN Boiler adopted a skid-mounted delivery solution, integrating the boiler body and auxiliary equipment to suppo...
    16 Jun 2026

Find the Right Boiler For You

Name *

Email *

WhatsApp/WeChat

Products

Power/Capacity