zozen boiler
Home Service FAQs FAQ of circulating fluidized bed boilers How to solve the problem of coking in circulating fluidized bed boiler operation?

How to solve the problem of coking in circulating fluidized bed boiler operation?

12 Jul 2018

(Question Details) Specific Performance:

(1) The bed temperature has risen sharply.

(2) The oxygen level drops even to zero.

(3) The current of the primary blower is reduced, and the wind pressure in the wind chamber is high and fluctuates.

(4) The furnace negative pressure increases and the induced draft fan current decreases.

(5) Difficulties in slagging.

(6) If coking in low temperature, the bed temperature, bed pressure distribution is uneven, the deviation is too large, the bed pressure, the plenum pressure, the bed temperature is not normal, and the local bed temperature measurement point is not normally raised or lowered.

(7) The bed pressure indicator value fluctuates little.

 

Answer: causes of failure :

(1) Improper operation, resulting in overheated bed temperature and coking.

(2) The primary air volume during operation is kept too small, which is lower than the minimum fluidized air volume, so that the material can’t be well fluidized but piled up, the temperature field of the entire furnace is changed, the burning share of the suspension stage is decreased, and the boiler output is reduced, if increase the amount of coal blindly at this time, it will inevitably cause overheating and coking.

(3) Bad fluidization caused by damaged hood.

(4) Recycling device blocking the ash and causing cycle interruption.

(5) The material pressure difference is too high.

 

Troubleshooting:

(1) Strengthen the combustion adjustment and increase the fluidization speed. If the material pressure difference is too high, the slag should be strengthened.

(2) If the bed temperature is too high, the coal supply will be reduced to zero,open the door with high negative pressure of the furnace, and remove the focal block with a hook.

(3) If the coking of furnace is serious, we should stop the operation of boiler.


Related FAQs View More
Related news View More
  • Growing Demand for Coal-fired Boilers: ZOZEN Boiler Explores Indonesian Pulp and Paper Industry
    According to data from the Economic and Commercial Office of the Embassy of the Republic of Indonesia, the pulp and paper industry in Indonesia is showing a promising development trend. In 2021, the export volume of the pulp and paper industry reached $7.5 billion, accounting for 6.22% of non-oil and gas exports and 3.84% of the domestic gross domestic product (GDP) of the non-oil and gas processing industry. In this thriving industry, ZOZEN Boiler, with its various coal-fired boiler models, has...
    23 Apr 2024
  • ZOZEN Quality Miles Journey in the First Quarter of 2024
    Modern manufacturing has surpassed the traditional concept of production and processing by incorporating services as an indispensable component. As a well-established industrial boiler manufacturer, ZOZEN Boiler has been implementing its after-sales service plan, the "Quality Miles Journey," since 2018. This initiative comprehensively assesses aspects such as service attitude of engineers, equipment quality, automation level, safety performance, and appearance, aiming to provide users with safe ...
    16 Apr 2024
  • ZOZEN Boiler Forges a New Epoch of Green Energy Transition for Textile Industry
    Located in the Yangtze River Economic Belt, Jiangsu Province, with its 13 district-level cities all ranking among the top in China, has always been a manufacturing behemoth dedicated to the resource-efficient and environmentally friendly transformation of its economy, striving for comprehensive progress in both its economic and social fabric.   A Jiangsu-based Enterprise—ZOZEN Boiler   As a traditional cornerstone and vital sector for livelihoods within the province, the te...
    09 Apr 2024

Find the Right Boiler For You

Name *

Email *

Products

Power/Capacity