Home Service FAQs FAQ of circulating fluidized bed boilers How to solve the problem of coking in circulating fluidized bed boiler operation?

How to solve the problem of coking in circulating fluidized bed boiler operation?

12 Jul 2018

(Question Details) Specific Performance:

(1) The bed temperature has risen sharply.

(2) The oxygen level drops even to zero.

(3) The current of the primary blower is reduced, and the wind pressure in the wind chamber is high and fluctuates.

(4) The furnace negative pressure increases and the induced draft fan current decreases.

(5) Difficulties in slagging.

(6) If coking in low temperature, the bed temperature, bed pressure distribution is uneven, the deviation is too large, the bed pressure, the plenum pressure, the bed temperature is not normal, and the local bed temperature measurement point is not normally raised or lowered.

(7) The bed pressure indicator value fluctuates little.

 

Answer: causes of failure :

(1) Improper operation, resulting in overheated bed temperature and coking.

(2) The primary air volume during operation is kept too small, which is lower than the minimum fluidized air volume, so that the material can’t be well fluidized but piled up, the temperature field of the entire furnace is changed, the burning share of the suspension stage is decreased, and the boiler output is reduced, if increase the amount of coal blindly at this time, it will inevitably cause overheating and coking.

(3) Bad fluidization caused by damaged hood.

(4) Recycling device blocking the ash and causing cycle interruption.

(5) The material pressure difference is too high.

 

Troubleshooting:

(1) Strengthen the combustion adjustment and increase the fluidization speed. If the material pressure difference is too high, the slag should be strengthened.

(2) If the bed temperature is too high, the coal supply will be reduced to zero,open the door with high negative pressure of the furnace, and remove the focal block with a hook.

(3) If the coking of furnace is serious, we should stop the operation of boiler.


Related FAQs View More
Related news View More
  • ZOZEN Boiler Joins Hands with Guizhou Baijiu Enterprises for High-Quality Development
    As China advances the 14th Five-Year Plan and its long-range goals through 2035, green and low-carbon growth has become the main theme of high-quality development in manufacturing. Baijiu, a cultural emblem with a long Chinese heritage, is embracing greener production with renewed resolve. Guizhou, the heartland of sauce-aroma baijiu, is home to many renowned distilleries that are proactively responding to national calls for energy conservation, emissions reduction, and green transformation, whi...
    09 Sep 2025
  • ZOZEN’s diversified product lineup empowers green development for Jiangxi enterprises
    As Jiangxi’s industrial upgrade accelerates, local companies increasingly need environmentally friendly energy equipment. Wuxi ZOZEN Boiler is enabling green production and efficiency gains through customized solutions and a comprehensive product matrix that includes gas-fired steam boilers, gas-fired thermal oil heaters, and biomass boilers.   ZOZEN’s multi-series solutions drive green growth in Jiangxi   Let’s start with gas-fired steam boilers. Jiangxi Huiyin...
    02 Sep 2025
  • Breakthrough in Overseas Market: ZOZEN Biomass Steam Boiler Empowers Pakistan’s Textile Industry
    Recently, ZOZEN Boiler successfully delivered a DZW series 20-ton reciprocating grate biomass steam boiler to Kohinoor Mills, a renowned textile enterprise in Pakistan, supporting its transition to green and sustainable production. This collaboration not only underscores ZOZEN’s growing influence in overseas markets, but also highlights its technological innovation and professional service capabilities in the biomass boiler field.   ZOZEN Biomass Boiler Supports Pakistan’s T...
    26 Aug 2025

Find the Right Boiler For You

Name *

Email *

WhatsApp/WeChat

Products

Power/Capacity