Home Service FAQs FAQ of gas-fired(oil-fired) boilers What causes the burner motor of the gas-fired boiler not running?

What causes the burner motor of the gas-fired boiler not running?

24 Nov 2023

If the burner motor of a gas-fired boiler is not running, several issues could be at play. Diagnosing the problem involves checking various components and systems. Here are some common causes:

Electrical Issues: Check if there's an electrical supply to the motor. A tripped circuit breaker, blown fuse, or loose wiring could interrupt power supply to the motor.

Faulty Motor: The motor itself could be malfunctioning. Over time, motors can wear out or burn out due to electrical issues or mechanical failures.

Thermostat Problems: If the thermostat is not sending the correct signal to the boiler, the burner motor won't activate. Ensure the thermostat is set correctly and functioning.

Control Board Issues: The control board orchestrates the operation of various components. A faulty control board might not send the necessary signals to start the motor.

Safety Lockout: Gas boilers have built-in safety mechanisms. If the system is in a lockout state due to a previous fault, it will prevent the burner motor from running. Resetting the boiler might be necessary.

Pressure Switch Fault: If the boiler pressure is too low or too high, safety switches will prevent the burner motor from starting. Check the pressure gauge and ensure it's within the recommended range.

Overheating Protection: If the boiler previously overheated, a safety device might have tripped to prevent further operation. This needs to be reset or addressed by a technician.

Airflow Issues: If there is insufficient airflow for combustion (due to blocked vents, for example), safety systems may prevent the burner from starting.

Fuel Supply Issues: For the burner to operate, there needs to be an adequate supply of gas. Check for any issues with the gas supply line, such as closed valves or leaks.

Thermal Overload Protection: Some motors have built-in thermal overload protection that shuts down the motor if it overheats. Once it cools down, it may need to be manually reset.

Capacitor Problems: If the motor has a start or run capacitor, this component might be failing. Capacitors provide the necessary starting torque and running efficiency for the motor.

Regular Maintenance: Lack of maintenance can lead to several problems, including motor failure. Regular maintenance helps identify and resolve such issues before they lead to a breakdown.

If the motor isn’t running and the cause is not immediately apparent, it’s advisable to contact a qualified technician to diagnose and repair the boiler. Working on gas boilers, especially electrical and mechanical components, requires specific expertise and safety knowledge.

Related FAQs View More
Related news View More
  • ZOZEN Boiler in Shandong: Innovative Boiler Models Empower Diverse Production
    On the thriving industrial land of Shandong, the continuous demand for thermal energy supply from enterprises drives the transformation of the boiler industry. With profound technical expertise and ongoing innovation, ZOZEN Boiler remains at the forefront of providing high-quality, adaptable boiler models for various industries.   ZOZEN Boiler Provides Tailored Boiler Solutions for Shandong Industries   Looking back, the cooperation projects with Shandong Luhua Group and Shandong...
    29 Jul 2025
  • ZOZEN Gas Water Tube Boilers Make a Strong Entrance on Cable Industry
    In the industrial zone of Wen’an County, Xinghua Cable Co., Ltd. is making steady progress on its project with an annual production capacity of 11 million meters of wires, cables, and accessories, backed by an investment of RMB 520 million. Upon completion, the project is expected to create over 150 jobs and generate annual sales revenue of RMB 800 million, demonstrating promising prospects. As a key supplier of thermal energy equipment, ZOZEN Boiler is quietly supporting the development o...
    22 Jul 2025
  • ZOZEN Boiler Facilitates Power Plant “Oil-to-Gas” Upgrade
    On March 20, 2025, the Guizhou Jinyuan Zhijin “Replacing Small Units with Large Ones” Relocation Project (2×660 MW), under State Power Investment Corporation, successfully achieved the first ignition of its boiler. This project replaced traditional oil-fired ignition fuel with liquefied natural gas (LNG), setting a new precedent for employing clean energy in 660 MW ultra-supercritical “W” flame boilers. As a key equipment supplier for this project, ZOZEN Boiler prov...
    15 Jul 2025

Find the Right Boiler For You

Name *

Email *

WhatsApp/WeChat

Products

Power/Capacity