SZS series boiler is designed with longitudinal double drums and " D " type chamber structure. The furnace is on the right and convection tube bank is on the left. The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways. Around the furnace is membrane wall. Furnace and tube bundle are totally separated by the membrane wall at the left side of the furnace. The back part of convection tube bank is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, convection tube bank area, and then from left front part enters spiral fin coil economizer and condenser, and finally is discharged to atmosphere through chimney.
Boiler body uses the forced circulation in the high temperature area to make sure all heating areas can be cooled down and avoid vaporization; The explosion door and flame detector are equipped for safe and reliable operation. Comb plates are used between both sides of boiler and tube bundle to avoid leakage of condensate and gas caused by using refractory concrete as sealing material. Air proof test is done before delivery in the factory to guarantee any gas leakage problem.
Environment-friendly
Big combustion chamber equipped with Low emission combustion burner effectively reduce the NOx to 30mg/m3. Smoke duct and smoke outlet use internal insulation to reduce operating noise.
Combustion chamber uses full membrane water cooling wall structure and pressurized combustion without smoke mixture.
Energy-saving
Good quality alumina silicate fiber and fire clay insulation material are used and the boiler body temperature is controlled below 45℃ and greatly heat loss is reduced. Combustion chamber is designed with narrow distance tube membrane water cooling wall which has good air proof to reduce heat lost and increase boiler thermal efficiency. Internal inspection holes uses high-alumina refractory and manhole cover seal devices, solving superheat problem in this part caused by using refractory bricks.
Convenience
Manholes are placed on the front and back side of drums and inspection doors on back side of boiler easy to open for inspection and clean inner and outer parts.
Membrane structure are used in the front and back wall for boiler body and highly increased their lifespan to over 20 years.
The key processes including material cutting, rolling, drilling are done by advanced CNC machining process to reduce the assembly stress and extend boiler service lifetime.
Flutter prevention fastener is used for high temperature part convection tubes, which avoid convection tube cracking problem.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will be tested by radiographic inspection.







Model | Rated thermal power(MW) | Rated working pressure(MPa) | Rated output water temperature(℃) | Rated Feeding water temperature(℃) | Maximum transport size(m) (L×W×H) |
SZS7-1.0/115/70-Q | 7 | 1 | 115 | 70 | 7.9×3.4×3.4 |
SZS10.5-1.0/115/70-Q | 10.5 | 1 | 115 | 70 | 8.9×3.9×4.0 |
SZS14-1.25/115/70-Q | 14 | 1.25 | 115 | 70 | 8.6×3.9×3.8 |
SZS17.5-1.25/115/70-Q | 17.5 | 1.25 | 115 | 70 | 9.4×3.8×3.8 |
SZS21-1.25/130/70-Q | 21 | 1.25 | 130 | 70 | 10.1×4.2×4.2 |
SZS29-1.25/130/70-Q | 29 | 1.25 | 130 | 70 | 10.9×4.2×4.2 |
SZS46-1.6/130/70-Q | 46 | 1.6 | 130 | 70 | 11.0×Φ1.45 |
SZS58-1.6/130/70-Q | 58 | 1.6 | 130 | 70 | 11.1×Φ1.46 |
SZS70-1.6/130/70-Q | 70 | 1.6 | 130 | 70 | 12.0×Φ1.66 |
SZS116-1.6/130/70-Q | 116 | 1.6 | 130 | 70 | 12.5×Φ1.66 |

-
25 tph SZS condensing gas-fired boiler for lithium industry
Tianqi Lithium is a well-known supplier of lithium products in China. While achieving good operating results, it also insists on advocating the concep...
-
14 MW SZS condensing gas-fired hot water boiler for heating
Beijing Feitai Urban Construction Property Management Company mainly manages property management and boiler heating. The company manages 6 village com...
-
29 MW SZS gas-fired hot water boiler project for city heating
The gas-fired replace coal-fired heating project is one of the decontamination projects to improve air quality in Tianjin. As a result, the fifth gas-...
-
Hot water
-
Steam
-
YQ(Y)W series gas-fired/oil-fired horizontal thermal oil heater1400-14000 KW0.8-1.0 MPA
-
Steam
-
Email
-
Tel
0086-510-68530066
Chat online
-
01Understanding you needs
First, you can communicate with our professional boiler consultant through email, telephone, form or online chat.
Here are some questions to know about you,eg:
1. what are your energy types and energy saving requirements?
2. the use of your boiler environment?
3. what do you ask for the power of the boiler?
4. what are you facing at the moment? -
02Make your solution
Next, according to your needs and conditions of use, we will provide
energy saving and reliable boiler system solutions.
——“ Let your boiler operate more efficiently and economically” -
03Keep your business on track
We will regularly communicate with you to understand your boiler operation and guide according to your needs. If you have other needs, we will provide you with the first time. Include: