Not inspecting it often enough can lead to minor issues being missed, which can lead to major issues later and possibly injury.
Not checking a boiler system could have catastrophic results in the form of a boiler explosion. Fuel may explode due to unfound problems. The high temperatures generated by the boiler can also cause problems if the water level drops too low and the trip switch fails.
Biomass fuel can be applied to a biomass-fired boiler by treatment and compression molding. Commonly used are straw particles, rice husk particles, wood particles, sawdust particles, peanut rod particles, sugar aldehyde residue particles, palm shell particles and so on.
The dry bottom hopper is formed by bending the lower part of the water wall of the front and rear walls inward. The main function is to gather, cool and automatically discharge ash. It is also convenient for the connection and sealing of the lower header and the ash well.
The temperature of flue gas generated by a biomass-fired boiler is relatively high. But it is not corrosive. So, it is suitable to use heat resisting glass fiber needled felt bag which has a good use effect. Moreover, this kind of cloth bag is not very expensive.
In the case of a thermal oil heater in a high-temperature operation state, if it encounters an emergency situation of power failure, its correct treatment is:
When the circulating oil pump cannot operate normally due to power failure, the heat transfer oil in the furnace tube will exceed the allowable value in a short time due to the residual heat of the furnace. At this time, the cold oil switching valve should be opened to release the cold oil in the expansion tank. And sent to the oil storage tank. At the same time, wet coal pressure or emergency shutdown is required and needs to be completed within 5 minutes.
In addition, we need to pay attention to not to put the oil in the expansion tank clean, otherwise the system will inhale air and cause problems. An oil level mark can be made on the oil level of the oil storage tank. When the cold oil is replaced, the valve can be closed in time to avoid the expansion of the expansion tank and the oil storage tank.
Industrial boilers are welded from sturdy steel plates that are engineered to withstand intense heat and pressure - as a result of this thick steel, boilers can sometimes weigh as much as 165 tons! The construction of hot water boilers and steam boilers is very similar. They both feature a cylinder tube, otherwise known as the pressure vessel. The pressure vessel contains something called a flame tube, which is fired through a burner and a reversing chamber that feeds flue gases back through a second smoke tube. These flue gases are reversed again via an external reversing chamber. This reversing chamber sends the flue gases to the end of the boiler, in the third smoke tube pass. A major difference between hot water industrial boilers and the steam versions? Hot water boilers, as their name implies, are usually completely filled with hot water during their operation, while steam boilers are filled with water only until the ¾ mark, with the top fourth of the boiler reserved for steam.
The primary objective of an industrial boiler is the generation of steam. Steam is generated by heat transfer at a constant pressure. The fluid, which is initially in a liquid state, is heated, produces a variation in its phase and becomes saturated vapour.
This saturated steam can then be used for different applications such as sterilization, fluid heating or electricity generation.
Any boiler where the products of combustion flow on the inside of a tube with the heat transfer media (ex. water, steam, or hot oil) on the outside. The tubes can be orientated vertically, horizontally or at an angle.