Bolivia is the highest average altitude country in the world, local Bolivian companies have higher requirements for boilers than general boilers. As the altitude increases, the atmospheric pressure and the air density decrease accordingly, which adversely affects boiler combustion.
In view of this situation, ZOZEN technical team makes adjustments from the combustion system and exhaust system of boiler, fully considering the influence of low air pressure on boiler body design and combustion. By appropriately increasing the volume of the furnace to extend the residence time of the fuel in the furnace, and the problems of slow fuel burning speed and long burning time are solved.
This series of double-drum steam boilers adopts a full membrane wall structure with good sealing performance. It is designed with large furnace to ensure full combustion of fuel and the thermal efficiency is over 98%. Meanwhile, this series of gas-fired steam boilers has reliable water circulation. Besides, the arrangement of various safety devices such as explosion-proof doors and flame detectors make the boiler operation safer and more reliable.
The boiler body of WNS series boilers adopts wet-back structure. The combustion, water level, temperature and steam pressure of the boiler are automatically adjusted and protected, which can realize fully automatical operation to ensure safety and reliability. The large-diameter corrugated furnace of this boiler ensures sufficient combustion of natural gas. Combined with an advanced low NOx burner, it can easily achieve the requirement of NOx≤30mg/Nm3. In addition, the boiler is also equipped with energy-saving equipment at the end of the boiler flue, so that the boiler thermal efficiency can reach over 98%.
SZS series boiler is designed with longitudinal double drums and " D " type chamber structure. The furnace is on the right and convection tube bank is on the left. The body is fixed on the basement by middle and both end flexible supports and make the boiler expand horizontally sideways. Around the furnace is membrane wall. Furnace and tube bundle are totally separated by the membrane wall at the left side of the furnace. The back part of convection tube bank is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, convection tube bank area, and then from left front part enters spiral fin coil economizer and condenser, and finally is discharged to atmosphere through chimney.
ZOZEN engineer viewed the internal operation of the boiler from the observation hole;
Observed the running condition of the boiler from the outside;
Checked the external equipment of the boiler.