zozen boiler
HomeBoiler tagsboiler capacity 12000 liter

“boiler capacity 12000 liter”- related faq

  • How to estimate thermal efficiency of gas fired boilers? 2023-06-09
    There are several ways to estimate the thermal efficiency of gas-fired boilers:   1. Direct method: This method involves measuring the amount of fuel consumed and the amount of heat produced by the boiler. By comparing these two values, it is possible to calculate the thermal efficiency of the boiler.   2. Indirect method: The indirect method involves measuring various parameters such as flue gas temperature, ambient air temperature, and fuel consumption, and then calculating the t...
  • What are the differences between DZL and SZL (coal-fired) with the same capacity? 2021-02-12
    What are the differences between DZL and SZL (coal-fired) with the same capacity?
  • What is the gas consumption per hour of a 1 ton natural gas boiler? 2021-02-05
    Gas consumption per hour of natural gas boiler = boiler thermal efficiency / natural gas calorific value / boiler efficiency. The higher the efficiency of boiler use, the less gas consumption, which has inverse relationship between the two. Boiler efficiency has become a key point in assessing boiler quality.
  • How to select the steam boiler used for the packaging plant? 2020-09-25
    The steam boiler in the packaging plant is mainly used in the heating process before the raw paper is made into cardboard. In brief, it is using steam which contains no water in the drying process to improve the production efficiency and product quality of packaging cartons. As a result, it has high requirements for the steam and steam boiler, such as temperature, water content, rated evaporation capacity per unit time, etc., which are important parameters in the boiler selection.
  • What factors are related with the boiler efficiency of a coal-fired boiler? 2020-05-15
    Boiler efficiency is mainly depended on the amount of losses in the system. In high capacity pulverized coal fired boilers the total losses account to about 12 to 14%. Roughly 50% of the losses are governed by fuel properties like hydrogen in fuel, moisture in fuel and ambient air conditions. The other 50% losses are carbon loss and dry gas loss. The best efficiency in the boiler can be achieved if the losses are kept to the minimum. Since 50% of the losses are dependent on the fuel and ambient condition, the best efficiency can be achieved by properly tuning the other 50%, i.e. mainly carbon loss and dry gas loss.
  • What is the inlet pressure of a gas burner? 2020-05-01
    The inlet gas pressure is different for different capacity boiler, for example, the pressure for 2 ton steam capacity boiler is about 8~10KPa, while for 4 ton steam capacity boiler is about 12~25KPa. You can tell us the boiler capacity you want, we will help you to get the gas inlet pressure. 
  • What is the calculation method of the circulating water volume of a coal-fired hot water boiler? 2020-04-10
    The coal-fired boiler refers to the boiler uses various types of coal as fuel and converts the heat of coal to steam or hot water. There are generally two calculation methods of the circulating water volume of a coal-fired hot water boiler. One is to calculate the hourly water volume of one square meter and the other is to calculate the design parameter volume of every ton. As for the make-up water volume of this type of boiler, it is usually calculated as 1% to 3% of its total circulating water.
  • What is the standard gas consumption of 10 tph gas-fired steam boiler? 2020-02-21
    The gas consumption of 10 tph gas-fired boiler is related to technical parameters. Such as heating surface layout, heat preservation effect, heat loss, water capacity, etc. The calculation formula of gas consumption of 10 tph gas-fired boiler is as follows: =10 tph gas-fired boiler output÷ thermal efficiency ÷calorific value of natural gas = 6,000,000 kcal ÷ 0.98 ÷ 8,600 kcal / h = 712 m3 Therefore, the gas consumption of 10 tph gas-fired boiler is 712 m3/ h The gas consumption of the above gas-fired boiler is calculated at full capacity. In practice, the gas consumption changes with the operation load and operation conditions. In addition, if thermal efficiency of the gas-fired boiler is different, the gas consumption is different, too. The higher thermal efficiency is, the lower gas consumption is.