1.Primary air is used for transportation of fine coal particle from coal mill to boiler floor at different elevations as per requirement.
2.Primary air is used for preheating of moisturised coal in to the coal mill so that minimum energy is required for combustion of the same.
3.As we all know that only 23% oxygen is available in the air by weight. For combustion of huge quantity of coal inside the boiler very high quantity of oxygen is required. This oxygen requirement will be completed by secondary air which is supplied by FORCED DRAFT fans through ducts.
This secondary air is coming via air preheater hence its outlet temperature increases this will help in combustion and low heat input is required for combustion of coal.
The coal-fired steam boiler is a forced circulation high-pressure single-tube DC boiler. Its operation process includes three processes: the combustion process of the fuel, the heat transfer process of flue gas to water and the vaporization process after water absorbs heat. In order to better control these different processes, the control system should make
the heat of pulverized coal combustion adapt to the requirements of steam load changes and dryness.
Biomass fuel can be applied to a biomass-fired boiler by treatment and compression molding. Commonly used are straw particles, rice husk particles, wood particles, sawdust particles, peanut rod particles, sugar aldehyde residue particles, palm shell particles and so on.
1. The control system is equipped with a special computer controller, which makes the boiler running clear and easy to operate.
2. The burner is controlled by full-automatic program, and in case of failure, the burner stops automatically.
3. The boiler body is designed with reasonable structure, and the top is equipped with air vent. The boiler works under normal pressure and is far away from explosion danger. The full wet back three-way structure and corrugated tank design are adopted. The flue gas process is long, the temperature of exhaust gas is reduced, the heat transfer coefficient is increased, and the equipment life is prevented from being reduced due to the expansion and contraction of metal.
The thermal oil heater is a heater that uses heat medium oil as medium for heat transfer. The low-pressure and high-temperature heating can be realized by the utilization of the high-temperature characteristics of heat medium oil.If there is too much moisture in the low-temperature heat medium oil, there will be pressure fluctuations, which will cause some other problems. In addition, if the heat medium oil does not flow in the furnace owing to the stop of pump, the oil temperature will rise and exceed the limit value, which not will greatly affect the service life of the heater and cause the deterioration of the heat medium oil.
The proximate analysis of coal is to dry, heat and burn coal samples as required to get the percentage of moisture, volatiles, fixed carbon and ash in the coal and learn about the characteristics of coal combustion.
Fuel freezing point is the temperature at which the fuel loses fluidity. It is an important index that indicates the fuel flows at low temperatures. It often refers to the maximum temperature at which the oil surface remains stationary within 1 minute. The higher the fuel freezing point, the lower the low-temperature fluidity. When the oil temperature is below the freezing point, it cannot be transported in the pipeline.
1. If the stop valve of the oil circuit is closed or the feeding of oil is insufficient and the oil filter is blocked, it is necessary to check that the valve in the oil circuit is open, the oil filter works normally and clean the filter screen of the pump.
2. If the oil temperature is low, viscosity is too high or the temperature of the oil fed by pump is too high, the oil temperature needs to be increased or decreased.
3. If the the domestic sewage treatment equipment oil pump breaks down, the oil pump is required to be replaced.
4. If the bearing of fan motor is damaged, it is necessary to replace the motor or bearing.
5. If the fan impeller is too dirty, it is required to be cleaned.