1. If the stop valve of the oil circuit is closed or the feeding of oil is insufficient and the oil filter is blocked, it is necessary to check that the valve in the oil circuit is open, the oil filter works normally and clean the filter screen of the pump.
2. If the oil temperature is low, viscosity is too high or the temperature of the oil fed by pump is too high, the oil temperature needs to be increased or decreased.
3. If the the domestic sewage treatment equipment oil pump breaks down, the oil pump is required to be replaced.
4. If the bearing of fan motor is damaged, it is necessary to replace the motor or bearing.
5. If the fan impeller is too dirty, it is required to be cleaned.
1. The fuel volume is 1 / 30 ~ 40 of the raw material volume after molding;
2. The specific gravity is 10-15 times of the raw material, and the moisture content is between 12% and 18% (the moisture content of coal is below 10-15);
3. The net calorific value can reach 3500-4500 kcal (the net calorific value of class II bituminous coal is 3700-4700 kcal / kg);
4. The ash content is less than 10% (the ash content of coal is more than 20%);
5. Volatile matter ≥ 65.62% (volatile matter of class II bituminous coal≥20%).
6. Biomass fuel belongs to renewable clean energy, which is the same as wind energy and solar energy. The biomass fuel is rich in resources, it can ensure the sustainable use of energy.
7. The sulfur content and nitrogen content of biomass fuel are low, the amount of SOx and NOx generated in the combustion process is low.
The combustion air preheater is definitely one of heat exchanger applications. Based on Figure 1 below, flue gas simply leaves steam boiler and passes via air preheater. The combustion air is passed through this equipment too to increase its temperature before being combined with boiler fuel.
Because the temperature of combustion air is lower than the temperature of flue gas, combustion air receive heat transfer from flue gas through combustion air preheater in the process of convection heat transfer. The heat transfer make temperature of flue gas lower and consequently minimizes its heat loss and also decreases the air temperature to stack.
Economizer is one of steam boiler’s equipment which is used to heat feedwater before it is supplied into steam drum. Economizer is the heat exchanger equipment to increase boiler efficiency by absorbing heat recovery of flue gases. The lower temperature of flue gas out from stack, the heat loss will be less and the fuel which is needed to convert water into steam will be also less in certain circumstances. So it can be said that economizer can save the fuel efficiently. Economizer will make temperature of feedwater higher, so steam boiler can produce steam easily.
The boiler gas consumption calculation need the following parameters: gas calorific value and boiler thermal efficiency.
Theoretically, the gas consumption of boiler = boiler thermal capacity ÷ (calorific value of gas x boiler thermal efficiency )
Take the 1 tph steam boiler as an example:
= 600,000 cal / (8500Kcal * 0.98) =72m3/h, the 1 tph boiler's gas consumption per hour is about 72 cubic meters.
A fire tube steam boiler is a boiler where the combustion gases from the burner are channeled through tubes that are surrounded by the fluid to be heated. The boiler body is the pressure vessel and contains the fluid. In most cases, this fluid is water that will circulate for heating purposes or become steam for use in processing.
Each set of tubes through which the combustion gas passes, before making a turn, is considered a "step". Consequently, a three-step boiler will have three sets of pipes with the outlet located at the rear of the boiler.
In superheated industrial water boilers, the water is pressurized and boiled to 100°C producing steam. These boilers are pyrotubular, with a high volume of water and a large temperature exchange zone. The designs can adapt to temperatures and pressures according to needs.
We would recommend your biomass boiler has at least an annual maintenance service. Like anything if you maintain your boiler correctly it will last longer and perform better. Biomass boilers burning even the most difficult of materials can operate unattended, but weekly inspection visits are required to carry out a visual inspection of the boiler and fuel feed system, to check the lubrication of bearings and to empty the ashbin.
As a large enterprise specializing in manufacturing boilers, ZOZEN...