Economizer is one of steam boiler’s equipment which is used to heat feedwater before it is supplied into steam drum. Economizer is the heat exchanger equipment to increase boiler efficiency by absorbing heat recovery of flue gases. The lower temperature of flue gas out from stack, the heat loss will be less and the fuel which is needed to convert water into steam will be also less in certain circumstances. So it can be said that economizer can save the fuel efficiently. Economizer will make temperature of feedwater higher, so steam boiler can produce steam easily.
ead below for our top three benefits to purchasing a low NOx heater for your facility.
They're Environmentally Friendly
When NO2 and NOx are released, they interact with other chemicals in the atmosphere that is harmful to the environment. The EPA has linked NOx emissions contributing to acid rain, smog, global warming, and smog. By using a low NOx heater, you greatly reduce NO2 pollution in the atmosphere.
Interested in decreasing waste and emissions? Learn why your facility needs a waste recovery unit.
They're Safer For Your Employees
According to the EPA, exposure to nitrogen oxides has been found to contribute to respiratory problems and diseases, like asthma. By installing a low NOx heater, you're potentially preventing damage to your employee's lungs.
They're More Efficient
As our low NOx heaters are built using a serpentine coil technology, they have space between the coil tubes which renders them 10 to 15% more efficient that hot oil heaters that feature helical coils.
Gas fired boiler is a boiler which uses gas as its fuel. Gas fired boiler consists of some important components such as flame ignition, gas metering system, air compressor, air piping, gas piping, burner nozzles, and the others. Combustion process of gas fired boiler should be maintained and operated properly to produce efficient combustion result.
Evaporation phase occurs in water wall tubes. Evaporation is the process to convert water into steam. Therefore water wall tubes should be designed and constructed to provide high heat absorption, minimum excess air level and highest boiler efficiency. Construction of water wall tubes should be also constructed to prevent air leakage into steam boiler, eliminate amount of heat losses and permit high heat release and combustion rate in the furnace.
Construction of water wall tubes must provide high quality of the supporting component such as tubes, casing, refractory, lagging, tile, fin, and so on. Best construction will reduce heat loss and maintenance. Construction of water wall tubes can be classified into four types such as:
In a boiler, energy from the fuel is transferred to liquid water in order to create steam. Once the water is heated to boiling point, it is vaporized and turned into saturated steam. When saturated steam is heated above boiling point, dry steam is created and all traces of moisture are erased. This is called superheated steam.
If your boiler equipment freezes, you can expect a shutdown and significant loss of productivity. Winter can be tough on your boiler system. The experts at ZOZEN Boiler weigh in on what you can do to prevent your industrial boiler from freezing up.
Boiler controls provide an extra level of safety and reassurance: they allow you to understand your boiler's daily operations better, as well as perform the crucial duty of ensuring that your boiler is operating safely and efficiently. Regardless of what kind of industrial or commercial operation you run, here are some must-have boiler controls to get the most out of your equipment.
Here are some common issues that could cause your industrial boiler to misbehave.
1. Burner Not Functioning Correctly.
If the boiler burner fails or is faulty, then your boiler is not going to be able to generate heat efficiently, or in the worst case not at all . As industrial boilers are in almost constant use they are built to be very robust and last for decades, nevertheless they can still have problems with broken burners from time to time. Burner pumps, heads and nozzles can all cause problems but a swift replacement should limit your down time.