1. The control system is equipped with a special computer controller, which makes the boiler running clear and easy to operate.
2. The burner is controlled by full-automatic program, and in case of failure, the burner stops automatically.
3. The boiler body is designed with reasonable structure, and the top is equipped with air vent. The boiler works under normal pressure and is far away from explosion danger. The full wet back three-way structure and corrugated tank design are adopted. The flue gas process is long, the temperature of exhaust gas is reduced, the heat transfer coefficient is increased, and the equipment life is prevented from being reduced due to the expansion and contraction of metal.
The coal-fired boiler refers to the boiler uses various types of coal as fuel and converts the heat of coal to steam or hot water.
There are generally two calculation methods of the circulating water volume of a coal-fired hot water boiler. One is to calculate the hourly water volume of one square meter and the other is to calculate the design parameter volume of every ton. As for the make-up water volume of this type of boiler, it is usually calculated as 1% to 3% of its total circulating water.
The dry bottom hopper is formed by bending the lower part of the water wall of the front and rear walls inward. The main function is to gather, cool and automatically discharge ash. It is also convenient for the connection and sealing of the lower header and the ash well.
When the oil temperature rises to a certain temperature that the oil and gas molecules on the surface of the oil tend to saturate, can catch fire and maintain continuous combustion for a duration of not less than 5S. The temperature is called ignition point.
Fuel freezing point is the temperature at which the fuel loses fluidity. It is an important index that indicates the fuel flows at low temperatures. It often refers to the maximum temperature at which the oil surface remains stationary within 1 minute. The higher the fuel freezing point, the lower the low-temperature fluidity. When the oil temperature is below the freezing point, it cannot be transported in the pipeline.
Four factors are related to the failure of the draft fan of the biomass-fired boiler. The factors are electric, electrical motors, dampers and induced draft fans. Therefore, if the draft fan breaks down, you can check the electric and electrical motor first, then you can check the damper and the induced fan.
Biomass-fired boilers need to be shut down for maintenance. Proper maintenance can reduce the damage to the boiler caused by continuous work. Firstly, it is necessary to cut off all power to prevent being struck by lightning. In addition, dust, limescale and carbon deposits should be cleaned up to prevent rust and corrosion of the boiler.
The selection of a burner of the gas-fired thermal oil heater should be determined according to the boiler proper structure and fuel characteristics and in combination with the actual conditions and requirements. In addition, this kind of boiler can adopt a waste heat recovery device to improve thermal efficiency and reduce heat energy loss.