zozen boiler
HomeBoiler tagsfired with palm kernel shell

“fired with palm kernel shell”- related faq

  • What is volatile matter? Does it include moisture in coal? 2020-03-13
    Volatile matter in coal refers to the components of coal, except for moisture, which are liberated at high temperature in the absence of air. This is usually a mixture of short- and long-chain hydrocarbons, aromatic hydrocarbons and some sulfur. Volatile matter also evaluate the adsorption application of an activated carbon. The volatile matter of coal is determined under rigidly controlled standards. In Australian and British laboratories this involves heating the coal sample to 900 ± 5 °C (1650 ±10 °F) for 7 min. Also as the rank of coal increases the volatile matter decreases (AMK).
  • How to choose the dust collector for coal-fired boilers? 2020-02-07
    The selection of dust collector for coal-fired boilers is determined by the purpose and requirements of dust collecting. If the requirement is just dust collecting, the impulse bag filter is a good choice, the efficiency can reach up to 99%. If both dust collecting and desulfurization are required, you should choose bag filter plus spray desulfurization. Bag filter plus double alkali desulfurization is suggested for higher requirements.
  • What are the certain things about gas fired boiler that must obtain specific consideration? 2019-11-08
    Gas fired boiler is a boiler which uses gas as its fuel. Gas fired boiler consists of some important components such as flame ignition, gas metering system, air compressor, air piping, gas piping, burner nozzles, and the others. Combustion process of gas fired boiler should be maintained and operated properly to produce efficient combustion result.
  • What is the construction of an industrial boiler? 2019-10-04
    Industrial boilers are welded from sturdy steel plates that are engineered to withstand intense heat and pressure - as a result of this thick steel, boilers can sometimes weigh as much as 165 tons! The construction of hot water boilers and steam boilers is very similar. They both feature a cylinder tube, otherwise known as the pressure vessel. The pressure vessel contains something called a flame tube, which is fired through a burner and a reversing chamber that feeds flue gases back through a second smoke tube. These flue gases are reversed again via an external reversing chamber. This reversing chamber sends the flue gases to the end of the boiler, in the third smoke tube pass. A major difference between hot water industrial boilers and the steam versions? Hot water boilers, as their name implies, are usually completely filled with hot water during their operation, while steam boilers are filled with water only until the ¾ mark, with the top fourth of the boiler reserved for steam.
  • What are precautions to be carried out at Start in Steam Boilers? 2019-05-23
    1. Hydraulic should be carried out at a defined pressure before the start of a boiler.2. Check if the pump inlets are open at the start of a boiler.3. Install an automatic ash removal system such as rotary valves in a boiler so as to prevent the accumulation of ash in a furnace or other equipment. The accumulation may result in the blockage or excessive heating of boiler parts resulting in its failure.4. Pump priming must be done at the start of the boiler.5. All loose and wrong connections must...
  • How to deal with too much damage of the dust collecting cloth bag of the biomass-fired boiler? 2018-07-12
    Question details (Performance):Dust collecting cloth bag damages a lot. Answer: The cause of the problem: As the biomass-fired boiler fuel moisture is high, and bag material is general PPS, which will reduce the base fabric of the bag in the case of high temperature, high humidity, hydrolysis, oxidation, and cause damage; In addition, the fuel moisture is high and it cannot be completely burned in the furnace, so it burns in the dust collector, which is also an important reason for the damage of the cloth bag.Troubleshooting:(1) Design by full consideration of high fuel moisture, choosing the appropriate induced draft fan, if the existing design is not enough then consider change the induced draft fan.(2) If induced air volume is sufficient, a proper distribution of the first and second wind should be considered. Generally, the fuel with high moisture and light quality such as wood chips, straw and wheat straw hood, the secondary air volume should be increased. For bark, miscellaneous
1 2 3 4 5