Modular gas-fired boiler, according to the user's load and design needs, combines several independently operating module units into an integral boiler. By monitoring and calculating the changes of indoor and outdoor temperature and temperature of supply and return water, the computer automatic control system can control each level of modules, automatically adjust the number of modules to start and stop, make the output heat always match the actual required heat load, and ensure that each module ...
1. Water leakage on the inner wall: Water leakage on the inner wall can be divided into three types: boiler leakage, water wall leakage and downcomer leakage. If the leakage holes of boiler barrel and water wall are relatively small, it is ok to use steel with the same steel grade for patching and flaw detection. If the downcomer is leaking, it needs to be replaced.
2. The hand hole leaks: you can re-install it from another angle to see if the hand hole cover is deformed. If it is deformed, you...
What is a hot water boiler? Hot water boiler is a boiler that produces hot water. It refers to a kind of thermal equipment that uses the thermal energy released by fuel combustion or other thermal energy (such as electric energy, solar energy, etc.) to heat water to the rated temperature. Hot water boiler is widely used in all aspects of heating.
In the process of hot water boiler boosting, the essence of controlling the boosting speed is to control the heating speed, which requires that the te...
1. The defective parts in the last inspection.
2. Whether there are cracks and corrosion on the inner and outer surfaces of boiler pressure components, especially on openings, welds, edges and so on.
3. Whether the pipe wall is worn or corroded.
4. Whether there is any crack, fracture or corrosion at the brace of the boiler and the joint with the pulled element.
5. Whether the expansion port is tight, and whether there is annular crack in the expanded part of the pipe end.
6. Whether the ri...
1) The insufficient heating surface. In the process of retrofit design or improvement, increase the heating surface.
2) The particle size of the fuel is large, the screening characteristics do not meet the requirements, the material concentration in the suspension section is low, and the heat transfer coefficient is small, which makes the output unable to go up, or shows that the bed temperature is high and coal cannot be added. The solution is to improve the fuel preparation system and control...
Boiler output refers to the maximum continuous output of the boiler under rated parameters (pressure, temperature) and certain efficiency. For steam boilers, it is called rated evaporation, and the unit is tons/hour; For hot water boilers, it is called rated heat production, and the unit is MW.
What are the main factors affecting the output of gas-fired boilers? According to the analysis of ZOZEN Boiler engineers, there are many reasons for the insufficient output of gas-fired boilers,
...
Horizontal steam boiler structure
The horizontal internal combustion boiler has a large-diameter shell, in which a furnace is arranged, and the burner is placed in the furnace to form an internal combustion chamber. Both ends of the furnace are respectively connected with the front and rear tube plates, and the smoke tube is arranged between the front and rear tube plates, so there is no need for bricklaying walls outside the boiler. The structure is mainly composed of boiler shell, furnace, f...
Different users have different requirements for boiler configuration. For example, some users need NOx emission less than 30mg/Nm3, and some users only need it less than 80mg/Nm3. The better auxiliary equipment configuration is used, the price of boiler will naturally rise.
Different users have different requirements for the configuration of the whole boiler system, and the brand and quantity of auxiliary machines also affect the price. The better the brand, the more expensive the price. For ex...