Boiler efficiency is mainly depended on the amount of losses in the system. In high capacity pulverized coal fired boilers the total losses account to about 12 to 14%. Roughly 50% of the losses are governed by fuel properties like hydrogen in fuel, moisture in fuel and ambient air conditions. The other 50% losses are carbon loss and dry gas loss. The best efficiency in the boiler can be achieved if the losses are kept to the minimum. Since 50% of the losses are dependent on the fuel and ambient condition, the best efficiency can be achieved by properly tuning the other 50%, i.e. mainly carbon loss and dry gas loss.
If you smell gas, don’t use electrical switches, telephones, or any appliances that may cause sparks.Firstly, you should shut off the gas valve, open the doors and windows to circulate the air. Then you should seek for professional help:
The following conditions will occur when a gas-fired boiler is leaking:
The working pressure of natural gas changes.
There is a strong airflow sound near the source of the leak.
The hand-held alarm makes an abnormal sound.
If the boiler has a serious leakage, the fixed alarm will issue an automatic alarm and the exhaust fan will be opened automatically.
First of all, we should consider the thermal insulation effect. The main function of a gas-fired boiler is to provide heat energy. Good surface packaging material can avoid heat loss and save the fuel. It is suggested to choose glass wool which has a good insulation effect.
Secondly, we should consider the boiler appearance. It is best to choose a white color plate package when buying a gas-fired boiler, which not only has a beautiful appearance but also has a good insulation effect.
Finally, we should consider the boiler size. Wrong boiler size will cause some unnecessary troubles.
If the following three conditions occur during the burning and flame out process of a gas-fired boiler, the furnace is likely to blow up.
1.The residual gas content in the furnace reaches the ignition limit at the start-up phase of the furnace.
2.The fuel content in the furnace reaches the ignition limit after several times failure of ignition.
3.The fuel is sprayed out because of the halfway extinction of the flame. And, the temperature of the furnace can not meet the spontaneous combustion condition of the sprayed fuel. However, the content of the sprayed fuel reaches the ignition limit.
In the work of transforming a coal-fired boiler into a gas-fired boiler, the principle of changing the original boiler should be reduced without changing the pressure component of the boiler body. The transformation process should focus on the choice of gas burners, the determination of the number of burners, the layout of the burners, the matching design of the furnace layout, and the selection of explosion-proof measures. Step by step, both economic benefits and practicality should be considered.
The inlet gas pressure is different for different capacity boiler, for example, the pressure for 2 ton steam capacity boiler is about 8~10KPa, while for 4 ton steam capacity boiler is about 12~25KPa. You can tell us the boiler capacity you want, we will help you to get the gas inlet pressure.
1.Flamelifting caused by a sudden increase of gas pressure;
2.Gas supply disruptions caused by malfunction of solenoid valve;
3.Great gas constituent change and excessive moisture content.