  • What are the main factors related to the gas consumption of a gas-fired boiler? 2020-03-06
    Compared with the price of a traditional coal-fired boiler, the operation cost of a gas-fired boiler is relatively high. So, users need to consider the price and quality before purchasing a boiler. For a gas-fired boiler, the energy-saving performance is more important than the boiler price. One year is enough for a gas-fired boiler with good energy-saving performance to save the extra costs of the boiler proper. And, the gas consumption is an important indicator to measure the energy-saving performance of a boiler.
  • What are the disadvantages of a biomass-fired boiler? 2020-03-06
    Although biomass-fired boilers are environment-friendly boiler products, there are also some situations that biomass-fired boilers can’t be used. Main reasons as follows: Fuel restrictions: The fuels that contain synthetic compounds can’t be used as the fuel of a biomass-fired boiler, such as waste wood furniture, waste paper, production and domestic waste.
  • What is the reason that the pump of a biomass-fired is not pumping water? 2020-02-28
    1. If there is air in the pump or suction pipe, the air should be discharged. 2. If the depth of the bottom valve immersed in the water is not deep enough, the depth should be increased. 3. If the rotational speed is too slow or the conveyor belt is too loose, the rotational speed should be adjusted and the conveyor belt should be tightened. 4. If the impeller, suction pipe and bottom valve are blocked by dirt, you should check the pump body and clean the dirt. 5. If the height of water conveyance exceeds the regulations too much, the pump head should be adjusted to the specified range.
  • How to deal with insufficient fuel combustion of biomass-fired boilers? 2020-02-28
    1. Sufficient furnace temperature: Sufficient fuel combustion of biomass-fired boilers firstly requires high furnace temperature. The temperature should meet the requirements of sufficient fuel combustion. Besides, the combustion speed is required to be proportional to the temperature. Moreover, the furnace temperature should be raised as much as possible on the premise that slag is not formed in the furnace.
  • What reasons cause the increase of burner noise of a gas-fired boiler? 2020-02-21
    1. If the stop valve of the oil circuit is closed or the feeding of oil is insufficient and the oil filter is blocked, it is necessary to check that the valve in the oil circuit is open, the oil filter works normally and clean the filter screen of the pump. 2. If the oil temperature is low, viscosity is too high or the temperature of the oil fed by pump is too high, the oil temperature needs to be increased or decreased. 3. If the the domestic sewage treatment equipment oil pump breaks down, the oil pump is required to be replaced. 4. If the bearing of fan motor is damaged, it is necessary to replace the motor or bearing. 5. If the fan impeller is too dirty, it is required to be cleaned.
  • What is the standard gas consumption of 10 tph gas-fired steam boiler? 2020-02-21
    The gas consumption of 10 tph gas-fired boiler is related to technical parameters. Such as heating surface layout, heat preservation effect, heat loss, water capacity, etc. The calculation formula of gas consumption of 10 tph gas-fired boiler is as follows: =10 tph gas-fired boiler output÷ thermal efficiency ÷calorific value of natural gas = 6,000,000 kcal ÷ 0.98 ÷ 8,600 kcal / h = 712 m3 Therefore, the gas consumption of 10 tph gas-fired boiler is 712 m3/ h The gas consumption of the above gas-fired boiler is calculated at full capacity. In practice, the gas consumption changes with the operation load and operation conditions. In addition, if thermal efficiency of the gas-fired boiler is different, the gas consumption is different, too. The higher thermal efficiency is, the lower gas consumption is.
  • What is the function of the burner of the industrial boiler? 2020-02-21
    The function of the burner is to send the fuel and air into the furnace constantly, organize the air flow of pulverized coal reasonably and mix them well for rapid and stable ignition and combustion.
  • Why should oil be atomized prior to the oil combustion of oil-fired boilers? 2020-02-21
    The oil and air must be mixed for the combustion of the fuel droplets to take place. The combustion speed depends on the evaporation speed of oil droplets and the mixing speed of oil and air. The evaporation speed of oil droplets is related to the diameter and temperature of oil droplets. The smaller the fuel droplets, the higher the temperature and the faster the evaporation. On the other hand, it is conducive to mixing and combustion. The smaller the fuel droplets, the larger the air contract surface. Therefore, the fuel oil must be atomized before combustion. And, the oil can be heated and evaporated rapidly and fully burnt after it is injected to the furnace.