  • What are steam boilers with a low NOx system? 2019-06-14
    Steam boilers with a low NOx system are specially designed to minimize the environmental impact with the production of dry saturated steam. This type of boiler incorporates a stainless steel economizer with a cross flow integrated within the boiler and that, consequently, allows to reach maximum efficiency.In addition, it has a natural gas burner with low NOx emissions.
  • What is the main characteristic of industrial superheated water boilers? 2019-06-14
    In superheated industrial water boilers, the water is pressurized and boiled to 100°C producing steam. These boilers are pyrotubular, with a high volume of water and a large temperature exchange zone. The designs can adapt to temperatures and pressures according to needs.
  • What is a water tube boiler? 2019-06-06
    Any boiler where the products of combustion flow on the outside of a tube with the heat transfer media on the inside.
  • How do steam boilers work with biomass? 2019-06-06
    Biomass steam boilers recover the heat generated during the biomass combustion process to heat the water in the boiler exchanger circuit. The hot water is then diverted to the heating circuit. Occasionally it is necessary to remove the ashes generated by biomass combustion and clean the burner.  
  • What is a fire tube boiler? 2019-05-31
    Any boiler where the products of combustion flow on the inside of a tube with the heat transfer media (ex. water, steam, or hot oil) on the outside. The tubes can be orientated vertically, horizontally or at an angle.
  • Do I need another boiler as a back-up? 2019-05-31
    Many situations require one or more back-up boilers, especially those involving residential accommodation. A properly designed and installed biomass boiler will be as reliable as a fossil fuelled boiler, and in this respect the usual rules for specifying back-up boilers should be applied. However, as a biomass boiler is rarely sized to meet the peak load, the back-up boiler usually acts as a peak-topping boiler as well. Hence, it is usual for back-up boilers to be sized to meet the peak load.
  • What are precautions to be carried out at Start in Steam Boilers? 2019-05-23
    1. Hydraulic should be carried out at a defined pressure before the start of a boiler.2. Check if the pump inlets are open at the start of a boiler.3. Install an automatic ash removal system such as rotary valves in a boiler so as to prevent the accumulation of ash in a furnace or other equipment. The accumulation may result in the blockage or excessive heating of boiler parts resulting in its failure.4. Pump priming must be done at the start of the boiler.5. All loose and wrong connections must...
  • What maintenance does a biomass boiler require? 2019-05-10
    We would recommend your biomass boiler has at least an annual maintenance service. Like anything if you maintain your boiler correctly it will last longer and perform better. Biomass boilers burning even the most difficult of materials can operate unattended, but weekly inspection visits are required to carry out a visual inspection of the boiler and fuel feed system, to check the lubrication of bearings and to empty the ashbin. As a large enterprise specializing in manufacturing boilers, ZOZEN...