System load is measured in either BTUs or tons of steam (at a specific pressure and temperature). It would be nearly impossible to size and select a boiler(s) without knowing the system load requirements. Knowing the requirements leads to the following information:
The boiler(s) capacity, taken from the maximum system load requirement.
The boiler(s) turndown, taken from the minimum system load requirement.
Conditions for maximum efficiency, taken from the average system load requirement.
Determining the total system load requires an understanding of the type(s) of load in the system. There are three types of loads: heating, process, and combination.
The primary purpose of the boiler is to supply energy to the facility's operations – for comfort heating, manufacturing process, laundry, kitchen, etc. The nature of the facility's operation will dictate whether a steam or hot water boiler should be used. Hot water is commonly used in heating applications, with the boiler supplying water to the system at 120°F to 220°F. The operating pressure for hot water heating systems usually is 30 psig to 125 psig (hydrostatic). Under these conditions, there is a wide range of hot water boiler products available. If system requirements are for hot water of more than 250°F, a high-temperature water boiler should be considered.
This is because, under normal circumstances, the exhaust temperature of the boiler cannot completely condense the water in the flue gas, and the difference between the low calorific value and the high calorific value is mainly in the part of the latent heat of vaporization, so the low heat is used. The value is calculated to reflect the true efficiency of the boiler. However, there will be some special circumstances. For example, if the boiler is a condensing boiler, the calculation of the condensed water portion should be calculated using the high calorific value.
In order to improve the combustion efficiency of the boiler, in a large boiler, the combustion air is not supplied all at once, but is supplied in two times, one is supplied with the fuel that controls the rate of combustion as well as the amount of fuel that can be burned,and the other is directly supplied to the combustion process that that improves combustion efficiency. The primary air rate of the boiler refers to the proportion of the primary air. If the total air volume is 100% and the primary air rate is 70%, the secondary air rate is 30%.
The combustion air preheater is definitely one of heat exchanger applications. Based on Figure 1 below, flue gas simply leaves steam boiler and passes via air preheater. The combustion air is passed through this equipment too to increase its temperature before being combined with boiler fuel.
Because the temperature of combustion air is lower than the temperature of flue gas, combustion air receive heat transfer from flue gas through combustion air preheater in the process of convection heat transfer. The heat transfer make temperature of flue gas lower and consequently minimizes its heat loss and also decreases the air temperature to stack.
ASME code – also known by its longer name: ASME Boiler & Pressure Vessel Code – regulates the design, development, and manufacturing of boilers used in a variety of industries and applications.
This code was developed by the American Society of Mechanical Engineers, an organization that has been around for well over 100 years and is focused on establishing safety codes and standards for mechanical equipment.
Within the industrial heating industry, ASME code is the established standard that many pieces of equipment are built to.
Heating systems that adhere to the specifications set forth by ASME code have been constructed according to guidelines intended to promote safety and quality. As such, heating equipment that is ASME code compliant has been thoroughly inspected to assure that it meets high safety and quality standards.
Gas fired boiler is a boiler which uses gas as its fuel. Gas fired boiler consists of some important components such as flame ignition, gas metering system, air compressor, air piping, gas piping, burner nozzles, and the others. Combustion process of gas fired boiler should be maintained and operated properly to produce efficient combustion result.
If your boiler equipment freezes, you can expect a shutdown and significant loss of productivity. Winter can be tough on your boiler system. The experts at ZOZEN Boiler weigh in on what you can do to prevent your industrial boiler from freezing up.