With the industrial innovation and the advance of science and technology, steam engine is replaced by gas-fired boiler that is a kind of more energy-saving heat production machine. There are three main usages of gas-fired boiler that we need to know in order to better understand the benefits that gas-fired boiler brings to us.
1. During the start-up process of the burner, if the burner repeatedly alarms and locks, it should be found out the reason, find the fault and eliminate it, and then press the reset button to inherit the start. Note: The continuous press of the reset button should not exceed 10 seconds
2. If the burner is not successful in one combustion, the natural gas boiler induced draft fan should be restarted, and the second combustion can be started after 5 minutes of ventilation.
3. In the normal operation era, the burner close to the thermal equipment department (such as the connecting flange, etc.) will be very hot, to prevent the formation of burns. Do not place flammable materials in the vicinity to avoid causing fire.
4. During the operation of natural gas-fired boilers, it is necessary to closely supervise the working conditions of hot water circulation pumps and natural gas-fired boiler pressures, natural gas distribution bags, pipeline valves, pressure gauges, flow meters, and water
Missing insulation reduces the system’s efficiency. Insulation helps hold heat in the system, and when the heat can dissipate, more fuel is needed to maintain proper temperature and pressure.
Since missing insulation may not be visible, the best way to detect it is with a thermal imager. If you don’t have a thermal imager as a part of your building’s operations, a plumber or other professional likely will carry one. If your energy costs have increased without a rise in the amount you use the boiler, suspect missing insulation and call to have the system inspected with a thermal imager.
The combustion air will be heated to the flame temperature. This heating cost money. If you have some waste heat to be used for preheating the combustion air it will pay.
The following conditions will occur when a gas-fired boiler is leaking:
The working pressure of natural gas changes.
There is a strong airflow sound near the source of the leak.
The hand-held alarm makes an abnormal sound.
If the boiler has a serious leakage, the fixed alarm will issue an automatic alarm and the exhaust fan will be opened automatically.
In the work of transforming a coal-fired boiler into a gas-fired boiler, the principle of changing the original boiler should be reduced without changing the pressure component of the boiler body. The transformation process should focus on the choice of gas burners, the determination of the number of burners, the layout of the burners, the matching design of the furnace layout, and the selection of explosion-proof measures. Step by step, both economic benefits and practicality should be considered.
The thermal oil heater is a heater that uses heat medium oil as medium for heat transfer. The low-pressure and high-temperature heating can be realized by the utilization of the high-temperature characteristics of heat medium oil.If there is too much moisture in the low-temperature heat medium oil, there will be pressure fluctuations, which will cause some other problems. In addition, if the heat medium oil does not flow in the furnace owing to the stop of pump, the oil temperature will rise and exceed the limit value, which not will greatly affect the service life of the heater and cause the deterioration of the heat medium oil.
Biomass-fired boilers need to be shut down for maintenance. Proper maintenance can reduce the damage to the boiler caused by continuous work. Firstly, it is necessary to cut off all power to prevent being struck by lightning. In addition, dust, limescale and carbon deposits should be cleaned up to prevent rust and corrosion of the boiler.