  • How to tell if a gas-fired boiler is leaking? 2020-05-08
    The following conditions will occur when a gas-fired boiler is leaking: The working pressure of natural gas changes. There is a strong airflow sound near the source of the leak. The hand-held alarm makes an abnormal sound. If the boiler has a serious leakage, the fixed alarm will issue an automatic alarm and the exhaust fan will be opened automatically.
  • How to transform a coal fired boiler into a gas fired boiler 2020-05-01
    In the work of transforming a coal-fired boiler into a gas-fired boiler, the principle of changing the original boiler should be reduced without changing the pressure component of the boiler body. The transformation process should focus on the choice of gas burners, the determination of the number of burners, the layout of the burners, the matching design of the furnace layout, and the selection of explosion-proof measures. Step by step, both economic benefits and practicality should be considered.
  • What is the inlet pressure of a gas burner? 2020-05-01
    The inlet gas pressure is different for different capacity boiler, for example, the pressure for 2 ton steam capacity boiler is about 8~10KPa, while for 4 ton steam capacity boiler is about 12~25KPa. You can tell us the boiler capacity you want, we will help you to get the gas inlet pressure. 
  • What is the reason that causes flameout of a gas-fired boiler 2020-05-01
    1.Flamelifting caused by a sudden increase of gas pressure; 2.Gas supply disruptions caused by malfunction of solenoid valve; 3.Great gas constituent change and excessive moisture content.
  • What are the characteristics of gas-fired boilers? 2020-04-24
    1. The control system is equipped with a special computer controller, which makes the boiler running clear and easy to operate. 2. The burner is controlled by full-automatic program, and in case of failure, the burner stops automatically. 3. The boiler body is designed with reasonable structure, and the top is equipped with air vent. The boiler works under normal pressure and is far away from explosion danger. The full wet back three-way structure and corrugated tank design are adopted. The flue gas process is long, the temperature of exhaust gas is reduced, the heat transfer coefficient is increased, and the equipment life is prevented from being reduced due to the expansion and contraction of metal.
  • What should we know about the heat medium oil of the thermal oil heater? 2020-04-17
    The thermal oil heater is a heater that uses heat medium oil as medium for heat transfer. The low-pressure and high-temperature heating can be realized by the utilization of the high-temperature characteristics of heat medium oil.If there is too much moisture in the low-temperature heat medium oil, there will be pressure fluctuations, which will cause some other problems. In addition, if the heat medium oil does not flow in the furnace owing to the stop of pump, the oil temperature will rise and exceed the limit value, which not will greatly affect the service life of the heater and cause the deterioration of the heat medium oil.
  • What is the working principle of the oil-gas separator of a thermal oil heater? 2020-04-17
    Generally, there is moisture in heat medium oil. And, the moisture will be evaporated during the heating process of the oil. If the water vapor is not discharged from the thermal oil heater, it will cause the fluctuation of heat medium oil pressure. However, the oil-gas separator can separate the water vapor from the heat medium oil and discharge it from the heater, which ensures the stable oil pressure.
  • What is the function of the storage tank of a thermal oil heater? 2020-03-27
    1. The storage tank is used to store the heat medium oil of the heating system; 2. The storage tank is used to receive the overrunning heat medium oil; 3. The storage tank is used to supplement heat medium oil for the heating system; 4. The storage tank should be placed at the lowest position of the system; 5. A firewall should be placed between the storage tank and the thermal oil heater; 6. The storage tank should be operated at a low liquid level.