  • What are the characteristics of the thermal oil heater? 2020-11-06
    The thermal oil heater, also called organic heat carrier boiler, provides heat energy for production by heating the heat medium oil. It can realize the high-temperature and low-pressure heating without constant water supply. What are the characteristics of the thermal oil heater?
  • What is the classification of burner for gas-fired or oil-fired boiler from the perspective of atomization mode? 2020-08-14
    From the perspective of atomization mode, there are three kinds of burner used by boiler that are rotating cup atomization burner, pressure atomization burner and medium atomization burner.
  • Does the biomass-fired boiler need to be shut down for maintenance? 2020-04-03
    Biomass-fired boilers need to be shut down for maintenance. Proper maintenance can reduce the damage to the boiler caused by continuous work. Firstly, it is necessary to cut off all power to prevent being struck by lightning. In addition, dust, limescale and carbon deposits should be cleaned up to prevent rust and corrosion of the boiler.
  • What is a package boiler? 2019-11-29
    Package boiler is a boiler that had been fabricated and available as a complete package. The entire pressure parts have been assembled in the workshop and ready to be sent to the field or site where power plant is located. On the field/site requires only connection and integration of course work in electrical connections, water pipes, steam pipes and fuel piping system to operate. Package boiler is one of classification of boiler based on erection. Design package boilers in general are the type of Fire Tube Boiler and have made up shell and tubes. This type has high heat transfer both radiation and convection.
  • What is the reason for pump in the gas-fired boiler does not transfer oil? 2018-07-12
    Question details (performance):A pump in a gas boiler does not transfer oil. Answer: Fault reason:(1) Pump failure.(2) Oil pressure and power are reduced.(3) The oil inlet valve is not sealed.(4) The inlet pipe is not sealed.(5) The interceptor valve is closed.(6) The filter is contaminated.(7) The filter is not sealed.(8) The tubing is not sealed.(9) Pump suck air inlet.(10) The vacuum degree in oil tube is too high.Troubleshooting:(1) Replace with new pump.(2) Remove the inlet valve and clean or replace it.(3) Seal the inlet pipe.(4) Open.(5) Cleaning.(6) Replace the sealing ring.(7) Tighten and exhaust.(8) Clean the filter and valve.