Ash accumulation on the heating surface.
The scaling and ash deposition on the water-cooled wall of the furnace and the ash deposition of the superheater, convention tube bundles, economizer and preheater can increase the thermal resistance of the flue gas, weaken the heat transfer, lessen the cooling effect of the flue gas and increase the exhaust gas temperature of the gas-fired boiler.
Too high excess air coefficient.
Under normal circumstances, as the furnace outlet excess...
A condensing boiler can condense the water vapour in the flue gases and withstand the corrosive and acidic qualities of the flue gas condensate. Although most boilers can condense the flue gasses, only boilers that have heat exchangers constructed from materials able to withstand the corrosion should be used in condensing application. Condensing boilers with primary and secondary heat exchanger do not work well as they are not able to fully condense and defeat the purpose of using a condensing boiler. Also, boilers with this arrangement are prone to condensation in the primary heat exchanger at lower firing rate which can cause damage to the heat exchanger.
The most obvious use of boilers in any building, including hospitals, is typically heating for the facility. A reliable steam boiler is one of the most economical ways to provide heat across a large space, especially one with multiple floors.
Oil Fired Boilers generally require Day Oil Tank to store oil and this oil is transported to a burner through oil piping and oil pump. On the other hand, High-Efficiency Gas Fired Boilers are exactly same as Oil Fired Boilers in construction and the only difference is the transportation of gas to burner requires gas train which comprises of the gas regulator that regulates pressure, the gas strainer to remover dirt from gas while no such valves are required in oil fired boilers.
The packaged boiler is so called because it comes as a complete package with burner, level controls, feedpump and all necessary boiler fittings and mountings. Once delivered to site it requires only the steam, water, and blowdown pipework, fuel supply and electrical connections to be made for it to become operational.
As we all know, the stable operation of the natural gas boiler can significantly optimize the operation of the boiler, improve the efficiency of the boiler, and effectively reduce the operating cost of the boiler after effective maintenance. So, what factors will affect the stable operation of natural gas boilers?
Gas consumption per hour of natural gas boiler = boiler thermal efficiency / natural gas calorific value / boiler efficiency. The higher the efficiency of boiler use, the less gas consumption, which has inverse relationship between the two. Boiler efficiency has become a key point in assessing boiler quality.
The automatic boiler water level controller is mainly composed of hardware and software parts to complete the functions of the control system. The hardware part is mainly composed of the water level detection circuit, drive circuit, water level indication circuit, pressure automatic control simulation, manual control, etc. The software part is mainly composed of the programs written in assembly language.