If the boiler burner fails or is faulty, then your boiler is not going to be able to generate heat efficiently, or in the worst case not at all . As industrial boilers are in almost constant use they are built to be very robust and last for decades, nevertheless they can still have problems with broken burners from time to time. Burner pumps, heads and nozzles can all cause problems but a swift replacement should limit your down time.
Soot on the heating surfaces. Even a thin layer of soot will reduce the boiler efficiency. Not the right fuel for the burner. For instance, diesel oil to a rotary cup burner wouldn't do. Too low feed water temperature.
If you smell gas, don’t use electrical switches, telephones, or any appliances that may cause sparks.Firstly, you should shut off the gas valve, open the doors and windows to circulate the air. Then you should seek for professional help:
The following conditions will occur when a gas-fired boiler is leaking:
The working pressure of natural gas changes.
There is a strong airflow sound near the source of the leak.
The hand-held alarm makes an abnormal sound.
If the boiler has a serious leakage, the fixed alarm will issue an automatic alarm and the exhaust fan will be opened automatically.
First of all, we should consider the thermal insulation effect. The main function of a gas-fired boiler is to provide heat energy. Good surface packaging material can avoid heat loss and save the fuel. It is suggested to choose glass wool which has a good insulation effect.
Secondly, we should consider the boiler appearance. It is best to choose a white color plate package when buying a gas-fired boiler, which not only has a beautiful appearance but also has a good insulation effect.
Finally, we should consider the boiler size. Wrong boiler size will cause some unnecessary troubles.
If the following three conditions occur during the burning and flame out process of a gas-fired boiler, the furnace is likely to blow up.
1.The residual gas content in the furnace reaches the ignition limit at the start-up phase of the furnace.
2.The fuel content in the furnace reaches the ignition limit after several times failure of ignition.
3.The fuel is sprayed out because of the halfway extinction of the flame. And, the temperature of the furnace can not meet the spontaneous combustion condition of the sprayed fuel. However, the content of the sprayed fuel reaches the ignition limit.
The inlet gas pressure is different for different capacity boiler, for example, the pressure for 2 ton steam capacity boiler is about 8~10KPa, while for 4 ton steam capacity boiler is about 12~25KPa. You can tell us the boiler capacity you want, we will help you to get the gas inlet pressure.
1.Flamelifting caused by a sudden increase of gas pressure;
2.Gas supply disruptions caused by malfunction of solenoid valve;
3.Great gas constituent change and excessive moisture content.