An Interlock in the boiler’s control system is a programmed or hardwired condition that forces a device to be in a pre-determined or permissive state before the process can continue.
Depending on design pressure, fuel type, either liquid, gas or solid, all steam boiler require interlocks to sequence the operation and to prevent damage to the boiler. Examples of such devices are High or Low Boiler Drum Water Level, Low Boiler Feed Pump Pressure, High or Low Fuel pressure, High or Low Atomization pressure (oil fired), Proof of Ignition, Proof of Flame, FD and/or ID (solid fuel) Fan Motor Operation or combustion air pressure, Damper or Valve position and High Boiler Steam Pressure as well as O2 and furnace temperature.
In boilers, economizers are heat exchange devices that heat fluids, usually water, up to but not normally beyond the boiling point of that fluid. Economizers are so named because they can make use of the enthalpy in fluid streams that are hot, but not hot enough to be used in a boiler, thereby recovering more useful enthalpy and improving the boiler's efficiency. They are a device fitted to a boiler which saves energy by using the exhaust gases from the boiler to preheat the cold water used to fill it (the feed water).
Biogas is the mixture of gases produced by the breakdown of organic matter in the absence of oxygen (anaerobically), primarily consisting of methane and carbon dioxide. Biogas can be produced from raw materials such as agricultural waste, manure, municipal waste, plant material, sewage, green waste or food waste. Biogas is a renewable energy source.
Biogas is a byproduct of the decomposition of organic matter by anaerobic bacteria. Biogas is typically composed of 60% methane and 40% CO2...
People assume that owning a biomass boiler is no different from owning its less environmentally friendly cousins, the oil and gas boilers. Nothing could be further from the truth, and it is this very misconception which leads to abuse and neglect of the maintenance that a biomass boiler needs, if it is to retain its environmental and economic saving potential. This is especially true given the tendency of many installers to skimp on providing the proper support services and education to their customers.
A condensing boiler can condense the water vapour in the flue gases and withstand the corrosive and acidic qualities of the flue gas condensate. Although most boilers can condense the flue gasses, only boilers that have heat exchangers constructed from materials able to withstand the corrosion should be used in condensing application. Condensing boilers with primary and secondary heat exchanger do not work well as they are not able to fully condense and defeat the purpose of using a condensing boiler. Also, boilers with this arrangement are prone to condensation in the primary heat exchanger at lower firing rate which can cause damage to the heat exchanger.
One of the biggest issues related to natural gas explosions is that in the industrial world, people just don’t understand that natural gas piping repairs are different from other piping repairs.
Three-pass steam boilers are so-called because the combustion gases that are produced inside them in the burner go round a circuit that has three parts before leaving it:
Oil Fired Boilers generally require Day Oil Tank to store oil and this oil is transported to a burner through oil piping and oil pump. On the other hand, High-Efficiency Gas Fired Boilers are exactly same as Oil Fired Boilers in construction and the only difference is the transportation of gas to burner requires gas train which comprises of the gas regulator that regulates pressure, the gas strainer to remover dirt from gas while no such valves are required in oil fired boilers.