  • What causes the black smoke in gas-fired boilers? 2023-12-01
    Black smoke in gas-fired boilers is typically an indication of incomplete combustion, where the fuel is not being burned efficiently. This can happen due to several reasons: Poor Air-to-Fuel Ratio: The most common cause of black smoke is an improper balance between the air and fuel. Too much fuel or insufficient air leads to incomplete combustion, resulting in black smoke due to unburnt carbon particles. Dirty or Clogged Burners: Over time, burners can become dirty or clogged, affecting the ef...
  • Why gas-fired boiler chimney drops water? 2023-12-01
    If you notice water dripping from a gas-fired boiler's chimney, it could be due to condensation, which is a common issue in high-efficiency boilers. Here are some key reasons and explanations for this phenomenon: Condensation of Flue Gases: Modern high-efficiency gas boilers are designed to extract as much heat as possible from the combustion gases before they are expelled through the chimney. This process can cool the gases to a point where the moisture in them condenses into water. This is mo...
  • What if boiler cannot be ignited in the operation when the pressure is normal? 2023-12-01
    Question details (performance):Fail ignite, normal pressure, has electricity.Answer: Fault reason:1. The ignition transformer is burnt out.2. The high-voltage wire is damaged or detached.3. The clearance is too large or too small, and the relative size of the ignition rod position is wrong.4. Electrode rupture or grounded short circuit.5. Improper spacing. Troubleshooting:1. Replace with a new one.2. Reinstall or replace.3. Readjustment.
  • Why doesn't the gas-fired boiler ignite despite running burner motor and voltage at controller? 2023-11-24
    If the burner motor of a gas-fired boiler is running and voltage is present at the controller terminal, but there is no ignition followed by a system failure and stop, this situation can be attributed to several potential issues. Here's a breakdown of what might be happening and what to check: Ignition System Failure: The ignition system, which may include spark electrodes or an igniter, could be faulty. Check for any signs of damage, misalignment, or dirt on the igniter or electrodes. Control...
  • What causes the burner motor of the gas-fired boiler not running? 2023-11-24
    If the burner motor of a gas-fired boiler is not running, several issues could be at play. Diagnosing the problem involves checking various components and systems. Here are some common causes: Electrical Issues: Check if there's an electrical supply to the motor. A tripped circuit breaker, blown fuse, or loose wiring could interrupt power supply to the motor. Faulty Motor: The motor itself could be malfunctioning. Over time, motors can wear out or burn out due to electrical issues or mechanica...
  • What causes the combustion engine overheat during the operation of the gas-fired boiler? 2023-11-24
    Overheating in the combustion engine of a gas-fired boiler can be caused by several factors. Understanding and addressing these issues is crucial for maintaining the efficiency and longevity of the boiler, as well as for ensuring safety. Here are some common causes of overheating in the combustion engine of a gas-fired boiler: Insufficient Water Flow: If there isn't enough water flowing through the boiler, it can't absorb enough heat from the combustion process, leading to overheating. This cou...
  • Why doesn't the gas boiler's motor turn on after pressing the start button? 2023-11-24
    (Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
  • How much gas does a 1.2 million kcal gas boiler use in one hour? 2023-10-06
    When we talk about the gas consumption of a boiler, we are referring to the amount of natural gas or other types of gas fuel needed to generate a specific amount of heat energy. This consumption can be measured in various units, with kcal (kilocalories) being one of the most common. The question at hand pertains to a 1.2 million kcal gas boiler. Calculation Basis To determine the amount of gas required, you'll typically need the calorific value of the gas and the efficiency of the boiler. Let'...