Home Service FAQs FAQ of coal-fired boilers Why are the furnace tubes damaged in operation of coal-fired boilers?

Why are the furnace tubes damaged in operation of coal-fired boilers?

12 Jul 2018

(Question details) Specific performance:

The wall thickness of several boiler tubes was significantly reduced in a large area, the remaining wall thickness was 2.0mm, and some furnace tubes were corroded and worn out. Furnace tube wall is covered with a thick layer of uneven scale, the surface of the scale is brick red and black, scale layer is loose, and it is easy to remove the inner wall of the furnace tube, after removing, the furnace tube wall covered with a layer of corrosion pits. There is a thin layer of brick red corrosion on the outer wall of boiler tube, some of which are attached with black adhesive.

 

Answer: Fault reason:

1. The boiler is seriously short of water.

2. Poor water circulation and uneven combustion.

3. The unqualified quality of the boiler water and undemanding chemical supervision make the inner wall of the pipe corrode and scale, causing the pipe overheat and reduction of the strength.

4. Due to the presence of impurities and scale, the furnace tube is blocked inside, leading to bad water circulation, causing the pipe wall to overheat and causing drum and cracks.

5. The thermal strength of the furnace changes too much, and the fire raising speed is too fast or the water discharging is too early.

6. The welding quality of the boiler is unqualified, or the quality is not up to the standard, or the pipe manufacturing is defective.

7. Improper installation of boiler tube, header and water cooling wall tube or insufficient expansion allowance will affect free expansion of pipe.


Trouble shooting:

1. If damage is serious, circulating water pump power is not enough, boiler water pressure quickly reduce, in this case furnace should be emergent stopped and reduce circulating water outlet flow, in order to keep boiler water pressure, keep the induced draft fan continues to run, remove furnace flue gas and steam boiler.

2. If furnace tubes are not damaged so serious, and water lost small amount, water pressure of boiler can be kept in an normal value, and situation does not quickly going worse, in this case boiler load can be appropriately reduced, and proceed by normal boiler stop processing, but if damage keep going worse, and can't proceed by normal boiler stop, then  furnace should be emergent stopped.


Related FAQs View More
Related news View More
  • Export to Indonesia: ZOZEN Biomass Boiler Powered by Palm Kernel Shells Supports the Feed Industry
    With the global emphasis on sustainable energy and environmental protection, Indonesia, a leading producer of palm oil, has turned the energy utilization of palm kernel shells (PKS) — a byproduct of palm oil production — into a significant focus. As a renewable energy source, palm kernel shells are gaining traction in the feed industry, contributing not only to resource recycling but also reducing environmental impact.   The combustion properties of palm kernel shells make the...
    21 Jan 2025
  • ZOZEN Boiler Successfully Hosts 2025 Staff Meeting
    On January 15, 2025, Wuxi ZOZEN Boiler Co., Ltd. successfully hosted its annual staff meeting at the company headquarters. The theme of the event was "Rising Against the Tide—Innovation and Transformation in an Era of Intense Competition." The meeting aimed to review the past year's achievements, outline future development goals, and honor outstanding teams and individuals for their exceptional performance in 2024. 2025 Staff Meeting Officially Begins The meeting commenced under the gu...
    16 Jan 2025
  • ZOZEN Boiler Wins China Patent Excellence Award for Water Tube Gas/Oil Boiler
    ZOZEN Boiler has been honored with the China Patent Excellence Award in the 25th China Patent Awards, as announced by the National Intellectual Property Administration. The award recognizes ZOZEN’s innovative design patent for its water tube gas/oil boiler (Patent No. ZL 202030030831.X). This achievement not only highlights ZOZEN’s commitment to innovation in boiler design but also represents a groundbreaking milestone for the boiler industry as a whole. It reflects ZOZEN’s lea...
    14 Jan 2025

Find the Right Boiler For You

Name *

Email *

WhatsApp/WeChat

Products

Power/Capacity