Home Service FAQs FAQ of coal-fired boilers Why are the furnace tubes damaged in operation of coal-fired boilers?

Why are the furnace tubes damaged in operation of coal-fired boilers?

12 Jul 2018

(Question details) Specific performance:

The wall thickness of several boiler tubes was significantly reduced in a large area, the remaining wall thickness was 2.0mm, and some furnace tubes were corroded and worn out. Furnace tube wall is covered with a thick layer of uneven scale, the surface of the scale is brick red and black, scale layer is loose, and it is easy to remove the inner wall of the furnace tube, after removing, the furnace tube wall covered with a layer of corrosion pits. There is a thin layer of brick red corrosion on the outer wall of boiler tube, some of which are attached with black adhesive.

 

Answer: Fault reason:

1. The boiler is seriously short of water.

2. Poor water circulation and uneven combustion.

3. The unqualified quality of the boiler water and undemanding chemical supervision make the inner wall of the pipe corrode and scale, causing the pipe overheat and reduction of the strength.

4. Due to the presence of impurities and scale, the furnace tube is blocked inside, leading to bad water circulation, causing the pipe wall to overheat and causing drum and cracks.

5. The thermal strength of the furnace changes too much, and the fire raising speed is too fast or the water discharging is too early.

6. The welding quality of the boiler is unqualified, or the quality is not up to the standard, or the pipe manufacturing is defective.

7. Improper installation of boiler tube, header and water cooling wall tube or insufficient expansion allowance will affect free expansion of pipe.


Trouble shooting:

1. If damage is serious, circulating water pump power is not enough, boiler water pressure quickly reduce, in this case furnace should be emergent stopped and reduce circulating water outlet flow, in order to keep boiler water pressure, keep the induced draft fan continues to run, remove furnace flue gas and steam boiler.

2. If furnace tubes are not damaged so serious, and water lost small amount, water pressure of boiler can be kept in an normal value, and situation does not quickly going worse, in this case boiler load can be appropriately reduced, and proceed by normal boiler stop processing, but if damage keep going worse, and can't proceed by normal boiler stop, then  furnace should be emergent stopped.


Related FAQs View More
Related news View More
  • A Boiler Generating Steam for Brewed Aroma: ZOZEN Boiler Supports Green Production at Yanjing Beer
    As the beer industry moves toward greener, more continuous, and more refined production, the steam system has become an important part of brewing operations. Recently, the cooperation case between ZOZEN Boiler and Yanjing Beer (Guilin Liquan) Co., Ltd. once again highlighted the essential role and system value of industrial boiler equipment in the food and beverage industry. Industrial Heat and Beer Brewing Are Closely Connected From a Drop of Beer, the Value of Stable Steam Becomes ClearYan...
    24 Jun 2026
  • ZOZEN Skid-Mounted Boiler Exported to Thailand Supporting a Stationery Manufacturer
    Recently, ZOZEN Boiler delivered a 3-ton WNS series skid-mounted steam boiler to a stationery products manufacturer in Thailand. The customer mainly produces solid glue, crayons, oil pastels and other stationery products. During production, the customer has clear requirements for continuous and stable steam supply. Based on the customer’s process features and site conditions, ZOZEN Boiler adopted a skid-mounted delivery solution, integrating the boiler body and auxiliary equipment to suppo...
    16 Jun 2026
  • ASME Certification Supports ZOZEN Boiler’s Biomass Gas-Fired Boiler Export to Brazil
    Brazil is an important sugarcane-producing country, with a mature sugarcane sugar industry chain and abundant bagasse resources. According to project information, Brazil produces more than 200 million tons of bagasse annually. How to convert bagasse from an agricultural by-product into a usable resource has become one of the focuses for local sugar producers. ZOZEN SZS Series Gas-Fired Steam Boiler Exported to Brazil The project supported by ZOZEN Boiler is the “CNBC500 Carbonization S...
    09 Jun 2026

Find the Right Boiler For You

Name *

Email *

WhatsApp/WeChat

Products

Power/Capacity