Why is the water wall tube damaged when the circulating fluidized bed boiler operates?
(Question Details) Specific Performance:
(1) There are blasting sounds in the furnace, and the furnace chamber is under positive pressure. There is smoke emitted from the combustion chamber in a leakage. In severe cases, the explosion-proof door of the boiler body opens.
(2) Drum water level drops rapidly and the feedwater flow rate is not abnormally larger than steam flow. MFT acts when the water level is below -280mm.
(3) Drum pressure, steam flow rate, exhaust temperature decrease, smoke temperature difference increases on both sides.
(4) The negative pressure at the inlet of the flue and suction fan becomes smaller and the temperature difference between the two sides increased.
(5) Smoke temperature decreases at the inlet and outlet of the cyclone separator, and the temperature of the material returned is low.
(6) Bed pressure increases, bed materials clean, fluidization poof, bed temperature distributes unevenly and bottom slag discharge difficultly.
Answer:cause of failure:
(1) Fly ash wear thins the pipe wall.
(2) Defective membrane water wall.
Troubleshooting:
(1) If the water wall tube is not badly damaged and can maintain the normal position and the failure will not be expanded, the load can be appropriately reduced and the maintenance time can be shortened to run until the standby furnace is put into operation. If the standby furnace can’t be put into operation for a long time and the damage of the malfunctioning furnace is intensified, the furnace should be stopped immediately.
(2) If the normal water level cannot be maintained, stop the furnace immediately, stop the bottom material and circulating ash, keep the induced draft fan running, and stop the induced draft fan after the steam leakage is eliminated.
We are strictly in accordance with the provisions of the use of advanced automatic robot and welding machine to complete the manufacture of elbows and the welding between the elbow and flat steel, fully automated to ensure the accuracy of the distance between the two.
-
DHX coal-fired CFB (circulating fluidized bed) steam boilerLive Chat20-75 t/h1.25-1.6 MPa
-
QXX coal-fired CFB (circulating fluidized bed) hot water boilerLive Chat14-58 MW1-1.25 MPa
-
DHL series coal-fired steam boilerLive Chat20-75 t/h1.25-5.4 MPa
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat

-
At Guizhou Haocaitou Food Co., Ltd. in Tongren, Guizhou Province, a ZOZEN WNS series gas-fired steam boiler has been operating for five years as part of the company’s steam supply system. The WNS10-1.25-Q boiler, with a rated capacity of 10 t/h, serves as an important heat source for food production. In recent feedback, the customer noted that matching the equipment configuration to production requirements, along with ease of daily operation and maintenance, were key considerations when se...27 Oct 2026 -
From beverage and convenience food production to rice processing, boiler solutions should be selected according to fuel availability, steam demand and site conditions. Steam is commonly used for heating, sterilization and equipment cleaning in food processing. However, different products, production line configurations and fuel conditions create different boiler requirements. In addition to rated steam capacity, food manufacturers need to consider steam pressure, fuel supply, equipment layout a...20 Oct 2026 -
On October 1, 2026, local time, the three-day AHR Expo Mexico 2026 came to a close at the Expo Guadalajara Convention Center. The ZOZEN Boiler sales team traveled to Mexico to participate in the exhibition. At Booth 1847, the team presented industrial boiler products and used the event as an opportunity to learn more about industrial heat demand in Mexico and across Latin America. AHR Expo Mexico 2026 exhibition site At the entrance to the exhibition, the “AHR Expo Mexico 2026” s...13 Oct 2026