Why is the water wall tube damaged when the circulating fluidized bed boiler operates?
(Question Details) Specific Performance:
(1) There are blasting sounds in the furnace, and the furnace chamber is under positive pressure. There is smoke emitted from the combustion chamber in a leakage. In severe cases, the explosion-proof door of the boiler body opens.
(2) Drum water level drops rapidly and the feedwater flow rate is not abnormally larger than steam flow. MFT acts when the water level is below -280mm.
(3) Drum pressure, steam flow rate, exhaust temperature decrease, smoke temperature difference increases on both sides.
(4) The negative pressure at the inlet of the flue and suction fan becomes smaller and the temperature difference between the two sides increased.
(5) Smoke temperature decreases at the inlet and outlet of the cyclone separator, and the temperature of the material returned is low.
(6) Bed pressure increases, bed materials clean, fluidization poof, bed temperature distributes unevenly and bottom slag discharge difficultly.
Answer:cause of failure:
(1) Fly ash wear thins the pipe wall.
(2) Defective membrane water wall.
Troubleshooting:
(1) If the water wall tube is not badly damaged and can maintain the normal position and the failure will not be expanded, the load can be appropriately reduced and the maintenance time can be shortened to run until the standby furnace is put into operation. If the standby furnace can’t be put into operation for a long time and the damage of the malfunctioning furnace is intensified, the furnace should be stopped immediately.
(2) If the normal water level cannot be maintained, stop the furnace immediately, stop the bottom material and circulating ash, keep the induced draft fan running, and stop the induced draft fan after the steam leakage is eliminated.
We are strictly in accordance with the provisions of the use of advanced automatic robot and welding machine to complete the manufacture of elbows and the welding between the elbow and flat steel, fully automated to ensure the accuracy of the distance between the two.
-
DHX coal-fired CFB (circulating fluidized bed) steam boilerLive Chat20-75 t/h1.25-1.6 MPa
-
QXX coal-fired CFB (circulating fluidized bed) hot water boilerLive Chat14-58 MW1-1.25 MPa
-
DHL series coal-fired steam boilerLive Chat20-75 t/h1.25-5.4 MPa
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat
-
Under the Belt and Road Initiative, economic and cultural ties between China and Pakistan are growing ever stronger, with more frequent exchanges between businesses from both countries. Recently, ZOZEN Boiler’s Sales Director led a team to visit Pakistan, where they held a meaningful meeting with Kohinoor Mills, a leading local textile company. During the gathering, both sides exchanged honorary plaques and thoughtful gifts—gestures that not only celebrate past collaborations but als...08 Jul 2025
-
In the first half of 2025, as a leading enterprise in China’s industrial boiler sector, ZOZEN Boiler has actively expanded into global markets with an international vision and innovative drive. The company made impressive appearances at the Pakistan Textile Exhibition and the Russian HEAT&ELECTRO MACHINERY Expo, continuously expanding its brand influence and bringing efficient, environmentally friendly energy solutions to customers worldwide, contributing to the green upgrade of the in...01 Jul 2025
-
In Weihai, Shandong, the fish meal industry serves as a vital pillar of the local economy, now facing increasingly fierce market competition. Amid this landscape, enterprises are eager for energy solutions that are not only efficient and eco-friendly but also cost-effective. At this crucial moment, the ZOZEN triple drum biomass boiler has made a strong entrance, opening new paths for the local fish meal enterprises. ZOZEN Triple Drum Biomass Boiler: Paving a New Way for Fish Meal Enterprises ...24 Jun 2025