Why is the water wall tube damaged when the circulating fluidized bed boiler operates?
(Question Details) Specific Performance:
(1) There are blasting sounds in the furnace, and the furnace chamber is under positive pressure. There is smoke emitted from the combustion chamber in a leakage. In severe cases, the explosion-proof door of the boiler body opens.
(2) Drum water level drops rapidly and the feedwater flow rate is not abnormally larger than steam flow. MFT acts when the water level is below -280mm.
(3) Drum pressure, steam flow rate, exhaust temperature decrease, smoke temperature difference increases on both sides.
(4) The negative pressure at the inlet of the flue and suction fan becomes smaller and the temperature difference between the two sides increased.
(5) Smoke temperature decreases at the inlet and outlet of the cyclone separator, and the temperature of the material returned is low.
(6) Bed pressure increases, bed materials clean, fluidization poof, bed temperature distributes unevenly and bottom slag discharge difficultly.
Answer:cause of failure:
(1) Fly ash wear thins the pipe wall.
(2) Defective membrane water wall.
Troubleshooting:
(1) If the water wall tube is not badly damaged and can maintain the normal position and the failure will not be expanded, the load can be appropriately reduced and the maintenance time can be shortened to run until the standby furnace is put into operation. If the standby furnace can’t be put into operation for a long time and the damage of the malfunctioning furnace is intensified, the furnace should be stopped immediately.
(2) If the normal water level cannot be maintained, stop the furnace immediately, stop the bottom material and circulating ash, keep the induced draft fan running, and stop the induced draft fan after the steam leakage is eliminated.
We are strictly in accordance with the provisions of the use of advanced automatic robot and welding machine to complete the manufacture of elbows and the welding between the elbow and flat steel, fully automated to ensure the accuracy of the distance between the two.
-
DHX coal-fired CFB (circulating fluidized bed) steam boilerLive Chat20-75 t/h1.25-1.6 MPa
-
QXX coal-fired CFB (circulating fluidized bed) hot water boilerLive Chat14-58 MW1-1.25 MPa
-
DHL series coal-fired steam boilerLive Chat20-75 t/h1.25-5.4 MPa
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat
-
The continuous growth of the building materials industry places higher demands on thermal energy supply in production—stable steam output, efficient energy utilization, and emissions that meet environmental standards have become core criteria for selecting boiler equipment. Leveraging a deep understanding of industry-specific production needs, ZOZEN Boiler provides customized products and technical advantages to deliver reliable thermal energy support for building materials enterprises at ...21 Oct 2025
-
ZOZEN Boiler Breaks the High Humidity Biomass Combustion Challenge with DZW Series Reciprocating Grate Biomass Steam Boiler Recently, Jinzhi Morning Hong Paper Co., Ltd. (hereinafter referred to as "Morning Hong Paper") reached an important cooperation with ZOZEN Boiler, successfully introducing the DZW series reciprocating grate biomass steam boiler. This brings new impetus for efficient and green production to the company. As a leading paper product manufacturer in North China, Morning Hong P...14 Oct 2025
-
From October 21 to 23, the Heatpower Expo, Russia’s premier industrial boiler and heat exchange exhibition, will be held at the Crocus International Expo Center. As a benchmark event in the industrial boiler and heat exchange equipment sector in Russia, the expo serves as both a window into industry trends and a high-energy platform for fostering practical cooperation. ZOZEN Boiler’s Russian-speaking sales team will participate with its core boiler solutions, demonstrating clean, eff...07 Oct 2025