zozen boiler
HomeBoiler tags2Ton coal fuel steam boiler

“2Ton coal fuel steam boiler”- related faq

  • What is the heating load of an industrial boiler? 2024-01-19
    The heating load of an industrial boiler refers to the amount of energy required to generate a certain amount of heat in a specific period, usually measured in British Thermal Units (BTUs) per hour, kilowatts (kW), or megawatts (MW). Essentially, it's the amount of energy needed to heat the water or generate steam in the boiler for industrial processes or heating purposes. Understanding the heating load is crucial for several reasons: Boiler Sizing: Accurately determining the heating load is e...
  • Why doesn't the gas boiler's motor turn on after pressing the start button? 2023-11-24
    (Question details) specific performance:The gas boiler is powered on, press start, the motor does not turn. Answer: Fault reason:1. Insufficient pneumatic locking.2. The solenoid valve is not sealing, and there is air leakage at the joint. Check the lock.3. The thermal relay is open.4. At least one of the conditional circuits is not valid (water level, pressure, temperature and to check whether the program controller is energized to start). Troubleshooting:1. Adjust the air pressure to the requested value.2. Clean or repair solenoid valve pipe joint.3. Check whether the component is damaged and motor current by reset.4. Check whether the water level, pressure and temperature exceed the limit.ZOZEN gas-fired boiler adopts automatic control to control the operation, combustion, water level, temperature and steam pressure. In case of such problems, the system will automatically prompt the error code.
  • How often should steam boilers be serviced? 2023-08-11
    Typically, a steam boiler should receive servicing at least once per year. Any kind of safety failure with a boiler can have serious consequences, and so a yearly inspection will help to spot any safety issues that need to be addressed. Servicing your boiler on a regular basis can also help you to save money on repairs. If you spot a problem during routine maintenance, there's a good chance you'll be able to fix it at a much cheaper cost than if the problem goes unnoticed and becomes a larger and more serious issue.
  • How Boiler Economizers Work? 2023-03-29
    Boiler economizers are devices that help to improve the efficiency of industrial boilers by recovering heat from the flue gas and transferring it to the boiler feedwater. In this article, we will explore how boiler economizers work and the benefits they offer. We will also introduce ZOZEN's boiler and economizer solutions that can help improve the energy efficiency of your industrial operations. How Do Boiler Economizers Work? A boiler economizer is essentially a heat exchanger that recovers w...
  • What is the difference between steam and vapor? 2021-07-02
    The key difference between vapor and steam is that vapor is a generally used term while steam is the technical and specific term. A shared attribute between vapor and steam is the point of origin or how it is formed. Steam and other kinds of vapor are often made by evaporation or with other means or application of heat.
  • What are the chain grate types of coal-fired steam boilers? 2021-01-22
    The chain grate is the combustion equipment of coal-fired steam boiler. There are three main types and structures: chain belt grate, scale grate and beam grate.
  • How to effectively improve the thermal efficiency of thermal oil heater? 2020-09-04
    1) Set up the air preheater. One of the most effective measures to improve the thermal efficiency of thermal oil heater is to use an air preheater for heat recovery. 2) Use waste heat boiler for heat recovery. The waste heat boiler uses the waste heat in the flue gas exhausted from the thermal oil heater to heat water or generate steam.
  • What is a nonsteaming economizer? 2020-04-10
    If the final temperature of feed water doesn’t reach the saturated temperature after being heated by an economizer, (that is, the feed water has not reached the boiling state), we call the economizer as a nonsteaming economizer. Generally, the final temperature is 30-50℃ lower than the saturated temperature.