  • What is the oil ignition point of industrial boilers? 2020-04-03
    When the oil temperature rises to a certain temperature that the oil and gas molecules on the surface of the oil tend to saturate, can catch fire and maintain continuous combustion for a duration of not less than 5S. The temperature is called ignition point.
  • What is oil freezing point of industrial boilers? 2020-04-03
    Fuel freezing point is the temperature at which the fuel loses fluidity. It is an important index that indicates the fuel flows at low temperatures. It often refers to the maximum temperature at which the oil surface remains stationary within 1 minute. The higher the fuel freezing point, the lower the low-temperature fluidity. When the oil temperature is below the freezing point, it cannot be transported in the pipeline.
  • What is the function of the storage tank of a thermal oil heater? 2020-03-27
    1. The storage tank is used to store the heat medium oil of the heating system; 2. The storage tank is used to receive the overrunning heat medium oil; 3. The storage tank is used to supplement heat medium oil for the heating system; 4. The storage tank should be placed at the lowest position of the system; 5. A firewall should be placed between the storage tank and the thermal oil heater; 6. The storage tank should be operated at a low liquid level.
  • How to select a burner for the gas-fired thermal oil heater? 2020-03-20
    The selection of a burner of the gas-fired thermal oil heater should be determined according to the boiler proper structure and fuel characteristics and in combination with the actual conditions and requirements. In addition, this kind of boiler can adopt a waste heat recovery device to improve thermal efficiency and reduce heat energy loss.
  • How to judge the atomization performance of an oil gun? 2020-03-06
    The atomization performance of oil gun can be judged by atomization fineness, uniformity, diffusion angle, range and flow density. The oil droplets with good atomization quality are small and uniform, the range should be adjusted according to the furnace section, and the distribution of flow density should also be uniform.
  • What are the maintenance contents of main systems of a gas-fired boiler? 2020-03-06
    Maintenance of the burner: thoroughly clean the rotor plate, ignition device, filter, oil pump, motor and impeller system, and add lubricant to the connecting rod device of air valve. Retest the combustion condition.
  • What reasons cause the increase of burner noise of a gas-fired boiler? 2020-02-21
    1. If the stop valve of the oil circuit is closed or the feeding of oil is insufficient and the oil filter is blocked, it is necessary to check that the valve in the oil circuit is open, the oil filter works normally and clean the filter screen of the pump. 2. If the oil temperature is low, viscosity is too high or the temperature of the oil fed by pump is too high, the oil temperature needs to be increased or decreased. 3. If the the domestic sewage treatment equipment oil pump breaks down, the oil pump is required to be replaced. 4. If the bearing of fan motor is damaged, it is necessary to replace the motor or bearing. 5. If the fan impeller is too dirty, it is required to be cleaned.
  • Why should oil be atomized prior to the oil combustion of oil-fired boilers? 2020-02-21
    The oil and air must be mixed for the combustion of the fuel droplets to take place. The combustion speed depends on the evaporation speed of oil droplets and the mixing speed of oil and air. The evaporation speed of oil droplets is related to the diameter and temperature of oil droplets. The smaller the fuel droplets, the higher the temperature and the faster the evaporation. On the other hand, it is conducive to mixing and combustion. The smaller the fuel droplets, the larger the air contract surface. Therefore, the fuel oil must be atomized before combustion. And, the oil can be heated and evaporated rapidly and fully burnt after it is injected to the furnace.