Thermic fluid heater boilers are widely used in a variety of industries because of their excellent performance and energy efficiency. They offer several benefits over traditional steam boilers, including better temperature control, easy operation, and low maintenance costs. Here are some frequently asked questions about thermic fluid heater boilers:
1, What is a thermic fluid heater boiler?
A thermic fluid heater boiler is a device that uses thermal oil or heat transfer oil to transfer heat fr...
The coal-fired boiler uses coal as fuel. The consumption of coal is a key factor to measure the efficiency of boilers. Under the same condition, the coal-fired boiler with less coal consumption can save more costs for enterprises. However, the coal consumption of coal-fired boilers is related to many factors, such as the efficiency of the boiler, the calorific value of fuel coal and the degree of coal combustion.
Question details (Performance) :
1. The vibrating coal grate stops running totally or intermittently.
2. The current of vibrating coal grate motor rises abnormally.
3. The safety clutch of transmission machine of grate or safety pin is broken.
Answer: cause of the problem:
Boiler’s vibrating coal grate is a rotating combustion equipment, due to the bad working conditions, stuck stalling is easily happened and grate failure happens in daily application and ...
An Interlock in the boiler’s control system is a programmed or hardwired condition that forces a device to be in a pre-determined or permissive state before the process can continue.
Depending on design pressure, fuel type, either liquid, gas or solid, all steam boiler require interlocks to sequence the operation and to prevent damage to the boiler. Examples of such devices are High or Low Boiler Drum Water Level, Low Boiler Feed Pump Pressure, High or Low Fuel pressure, High or Low Atomization pressure (oil fired), Proof of Ignition, Proof of Flame, FD and/or ID (solid fuel) Fan Motor Operation or combustion air pressure, Damper or Valve position and High Boiler Steam Pressure as well as O2 and furnace temperature.
Definition of the tph meaning in boiler
When a steam boiler is continuously operated for a long period of time, the amount of steam generated per hour is called the evaporation amount of this boiler, and is usually used in tons per hour (t/h or tph).
A steam boiler is a steam device that uses heated energy or other thermal energy that is converted by the combustion of a fuel to heat the feed water to obtain specified parameters (temperature, pressure) and quality. 1tph means that the boi...
The boiler manhole-lids are mounted from the inside of the boiler so that the boiler pressure will help to keep them tight. Hence the manholes have to be elliptical in shape to make it possible to take the lid out from the boiler.
Before coking and boiling, check boiler parts detailedly. Inspection items are as follows:
1. Before coking and boiling, chain grate should be cold test run again and continuous running time shall not be less than 24 hours.
2. Ignition door can be opened flexibly, coal gate can be lift and dropped conveniently, coal gate left and right side is of the same distance to grate, and ensure the material layer thickness on both sides of the furnace is equal. If distance is not equal, it can be adjust...
1. After boiler body, economizer, air pre-heater, dust collector, etc are in place and installed, connect FD fan, ID fan, etc according to drawing and then connect corresponding flue gas duct. After fan in place, alignment between foundation and equipment base should be conducted with parallels. Fan position alignment should center on a shaft, central elevation deviation and vertical and lateral central line positional deviation should be 10mm or less and fan spindle should be in level state. Th...