An Interlock in the boiler’s control system is a programmed or hardwired condition that forces a device to be in a pre-determined or permissive state before the process can continue.
Depending on design pressure, fuel type, either liquid, gas or solid, all steam boiler require interlocks to sequence the operation and to prevent damage to the boiler. Examples of such devices are High or Low Boiler Drum Water Level, Low Boiler Feed Pump Pressure, High or Low Fuel pressure, High or Low Atomization pressure (oil fired), Proof of Ignition, Proof of Flame, FD and/or ID (solid fuel) Fan Motor Operation or combustion air pressure, Damper or Valve position and High Boiler Steam Pressure as well as O2 and furnace temperature.
Definition of the tph meaning in boiler
When a steam boiler is continuously operated for a long period of time, the amount of steam generated per hour is called the evaporation amount of this boiler, and is usually used in tons per hour (t/h or tph).
A steam boiler is a steam device that uses heated energy or other thermal energy that is converted by the combustion of a fuel to heat the feed water to obtain specified parameters (temperature, pressure) and quality. 1tph means that the boi...
The boiler manhole-lids are mounted from the inside of the boiler so that the boiler pressure will help to keep them tight. Hence the manholes have to be elliptical in shape to make it possible to take the lid out from the boiler.
Before coking and boiling, check boiler parts detailedly. Inspection items are as follows:
1. Before coking and boiling, chain grate should be cold test run again and continuous running time shall not be less than 24 hours.
2. Ignition door can be opened flexibly, coal gate can be lift and dropped conveniently, coal gate left and right side is of the same distance to grate, and ensure the material layer thickness on both sides of the furnace is equal. If distance is not equal, it can be adjust...
1. After boiler body, economizer, air pre-heater, dust collector, etc are in place and installed, connect FD fan, ID fan, etc according to drawing and then connect corresponding flue gas duct. After fan in place, alignment between foundation and equipment base should be conducted with parallels. Fan position alignment should center on a shaft, central elevation deviation and vertical and lateral central line positional deviation should be 10mm or less and fan spindle should be in level state. Th...
1. Burner should be installed in accordance with requirements of burner installation and operation manual.
2. Burner should be installed in the center of the reserved front wall hole, the embeded length should comply with the design requirements and the fixation should be reliable.
3. Burner center deviation shall not be more than +2mm and air adjustment actuator should be flexible.
4. Burner and boiler body junction surface should be sealed reliably, the position that needed to be sealed bet...
The design and construction of gas boiler room is also a very important point in boiler safety. How to install the gas boiler should also conform to the boiler room design specification, and it is necessary to comply with the site, space, protection and other aspects.
How to install the gas boiler?
How to install the gas boiler is mainly based on the Boiler Room Design Code and Boiler Safety Technical Inspection Code. In addition, the Urban Gas Design Code and the Fire Protection Code ...
As a clean fuel, natural gas has much lower sulfur content and nitrogen content than coal, and there is no ash in the fuel, and the flue gas produced after combustion is almost smoke-free. Therefore, a nationwide upsurge of coal to gas has been set off.
However, there are some problems in the process of gas boiler operation, among which the hardness, harm and treatment of gas boiler flue gas condensate are prominent.
When the boiler flue gas temperature is lower than the dew po...