zozen boiler
HomeBoiler tagsboiler controls

“boiler controls”- related faq

  • What is the advantages of a biomass-fired boiler? 2020-02-13
    Firstly, the combustion of biomass fuel is easy to control. The fuel is easy to ignite. Besides, the combustion speed is faster than that of coal. Secondly, the biomass-fired boiler can be ignited and extinguished at any time while the coal-fired boiler cannot. The biomass-fired boiler can also be ignited automatically. Thirdly, the biomass-fired boiler can achieve zero emission of sulfur dioxide, which belongs to environment-friendly boilers.
  • What are the characteristics of the pellet fuel used in biomass-fired boilers? 2020-02-13
    1. The fuel volume is 1 / 30 ~ 40 of the raw material volume after molding; 2. The specific gravity is 10-15 times of the raw material, and the moisture content is between 12% and 18% (the moisture content of coal is below 10-15); 3. The net calorific value can reach 3500-4500 kcal (the net calorific value of class II bituminous coal is 3700-4700 kcal / kg); 4. The ash content is less than 10% (the ash content of coal is more than 20%); 5. Volatile matter ≥ 65.62% (volatile matter of class II bituminous coal≥20%). 6. Biomass fuel belongs to renewable clean energy, which is the same as wind energy and solar energy. The biomass fuel is rich in resources, it can ensure the sustainable use of energy. 7. The sulfur content and nitrogen content of biomass fuel are low, the amount of SOx and NOx generated in the combustion process is low.
  • What is the process load of an industrial boiler? 2020-01-17
    A process load is usually a high-pressure steam load. A process load pertains to manufacturing operations, where heat from steam or hot water is used in the process. A process load is further defined as either continuous or batch. In a continuous load, the demand is fairly constant - such as in a heating load. The batch load is characterized by short-term demands. The batch load is a key issue when selecting equipment, because a batch-type process load can have a very large instantaneous demand that can be several times larger than the rating of the boiler. For example, based on its size, a heating coil can consume a large amount of steam simply to fill and pressurize the coil. When designing a boiler room for a process load with instantaneous demand, a more careful boiler selection process should take place.
  • Saturated Vs superheat steam conditions 2019-10-18
    In a boiler, energy from the fuel is transferred to liquid water in order to create steam. Once the water is heated to boiling point, it is vaporized and turned into saturated steam. When saturated steam is heated above boiling point, dry steam is created and all traces of moisture are erased. This is called superheated steam.
  • What is a fire tube steam boiler? 2019-07-05
    A fire tube steam boiler is a boiler where the combustion gases from the burner are channeled through tubes that are surrounded by the fluid to be heated. The boiler body is the pressure vessel and contains the fluid. In most cases, this fluid is water that will circulate for heating purposes or become steam for use in processing. Each set of tubes through which the combustion gas passes, before making a turn, is considered a "step". Consequently, a three-step boiler will have three sets of pipes with the outlet located at the rear of the boiler.
  • When should use high-pressure versus low-pressure steam? 2019-05-23
    The pressure of the steam is directly related to its temperature. So process temperature will require steam used to be at a specified pressure. For example, a process requires that needs temperatures at 150°C will require steam delivered at 6 Kg/cm2 or higher.
  • What are the main components of circulating fluidized bed boiler? 2019-03-21
    1. Primary air fan: after being heated by the air pre-heater, primary air enters into the wind chamber, then into the furnace through wind caps through the air distributor to fluidize particulate materials;2. Secondary air fan: after being heated by the air pre-heater, secondary air enters into the furnace through the secondary air ducts for complete combustion of fuels; the seal air, conveying air and fuel spreading air of the feeding device also adopt secondary air; 3. Circ...
  • Why is the water wall tube damaged when the circulating fluidized bed boiler operates? 2018-07-12
    (Question Details) Specific Performance:(1) There are blasting sounds in the furnace, and the furnace chamber is under positive pressure. There is smoke emitted from the combustion chamber in a leakage. In severe cases, the explosion-proof door of the boiler body opens.(2) Drum water level drops rapidly and the feedwater flow rate is not abnormally larger than steam flow. MFT acts when the water level is below -280mm.(3) Drum pressure, steam flow rate, exhaust temperature decrease, smoke temperature difference increases on both sides.(4) The negative pressure at the inlet of the flue and suction fan becomes smaller and the temperature difference between the two sides increased. (5) Smoke temperature decreases at the inlet and outlet of the cyclone separator, and the temperature of the material returned is low.(6) Bed pressure increases, bed materials clean, fluidization poof, bed temperature distributes unevenly and bottom slag discharge difficultly. Answer:cause of failure:(1) Fly ash
1 2 3 4