SZS series boiler is double drums, longitudinal arranged, "D" type chamber structure. Furnace is on right side and convection tube bundle is on the left, super heater is arranged at convection tube bundle. The body is fixed on the basement by middle and both end flexible supports and make the boiler to expand horizontally to sideways. Around furnace is membrane wall. Furnace and tube bundle is totally separated by the membrane wall at the left side of the furnace. The back part of bundle is sparse shift structure, front part is aligned structure. Smoke from furnace outlet enters re-burning chamber, bundle area, and then from left front part enters spiral fin coil economizer and condenser, finally discharged to atmosphere through chimney.
The YLW series thermal oil heater, with its horizontal layout and square coil tube design, uses a chain grate system for efficient fuel combustion. It incorporates mechanical features for solid fuel feeding, ventilation, and slag removal. During operation, fuel undergoes radiation and convection heat exchanges, proceeds to the waste heat boiler, and subsequently moves to the air preheater and dust remover. The remaining flue gas is then expelled into the atmosphere, resulting in optimal heat transfer and efficient industrial heating.