zozen boiler
HomeBoiler tagsboiler oil fired and gas firing

“boiler oil fired and gas firing”- related faq

Tags list
  • What is the calculation method of the circulating water volume of a coal-fired hot water boiler? 2020-04-10
    The coal-fired boiler refers to the boiler uses various types of coal as fuel and converts the heat of coal to steam or hot water. There are generally two calculation methods of the circulating water volume of a coal-fired hot water boiler. One is to calculate the hourly water volume of one square meter and the other is to calculate the design parameter volume of every ton. As for the make-up water volume of this type of boiler, it is usually calculated as 1% to 3% of its total circulating water.
  • What is oil freezing point of industrial boilers? 2020-04-03
    Fuel freezing point is the temperature at which the fuel loses fluidity. It is an important index that indicates the fuel flows at low temperatures. It often refers to the maximum temperature at which the oil surface remains stationary within 1 minute. The higher the fuel freezing point, the lower the low-temperature fluidity. When the oil temperature is below the freezing point, it cannot be transported in the pipeline.
  • What impact will excess air have on boiler performance? 2020-01-03
    Excess air provides safe operation above stoichiometric conditions. A burner is typically set up with 15% to 20% excess air in higher firing ranges. Higher excess air levels result in fuel being used to heat the air instead of transferring it to usable energy, increasing stack losses and significantly decreasing efficiency. Boilers with lower excess air throughout the operating range have higher efficiencies.
  • What are precautions to be carried out at Start in Steam Boilers? 2019-05-23
    1. Hydraulic should be carried out at a defined pressure before the start of a boiler.2. Check if the pump inlets are open at the start of a boiler.3. Install an automatic ash removal system such as rotary valves in a boiler so as to prevent the accumulation of ash in a furnace or other equipment. The accumulation may result in the blockage or excessive heating of boiler parts resulting in its failure.4. Pump priming must be done at the start of the boiler.5. All loose and wrong connections must...
  • What are the phenomena of coking on the circulating fluidized bed boilers? 2018-11-23
    The bed temperature rises sharply. Oxygen levels go down and sometimes drop to zero. The electric current of primary air fan is less and wind pressure of air compartment is higher. Negative pressure of furnace is increased while the electric current of induced draft fan is reduced. The slag discharge is difficult or unsuccessful. When appearing bed clinkering, the bed temperature and bed pressure will be uneven distributed and not at normal condition; the measuring point of part bed tempe...
  • How to deal with too much damage of the dust collecting cloth bag of the biomass-fired boiler? 2018-07-12
    Question details (Performance):Dust collecting cloth bag damages a lot. Answer: The cause of the problem: As the biomass-fired boiler fuel moisture is high, and bag material is general PPS, which will reduce the base fabric of the bag in the case of high temperature, high humidity, hydrolysis, oxidation, and cause damage; In addition, the fuel moisture is high and it cannot be completely burned in the furnace, so it burns in the dust collector, which is also an important reason for the damage of the cloth bag.Troubleshooting:(1) Design by full consideration of high fuel moisture, choosing the appropriate induced draft fan, if the existing design is not enough then consider change the induced draft fan.(2) If induced air volume is sufficient, a proper distribution of the first and second wind should be considered. Generally, the fuel with high moisture and light quality such as wood chips, straw and wheat straw hood, the secondary air volume should be increased. For bark, miscellaneous
  • Why are there percussive sounds and vibrations in the boiler drum or pipe of a coal-fired boiler? (water impact) 2018-07-12
    Question details (Performance):The steam pipe vibrates violently and has a dull impact sound.Answer:  fault reason: There is air in pipeline  ; automatic air vent valve is not turned on; or it is out of order. Troubleshooting: Check all the air release valves on the water supply pipe and the air release valves on the top of the boiler tube for gas storage. If the valve fails, it should be replaced immediately.