1. Sufficient furnace temperature: Sufficient fuel combustion of biomass-fired boilers firstly requires high furnace temperature. The temperature should meet the requirements of sufficient fuel combustion. Besides, the combustion speed is required to be proportional to the temperature. Moreover, the furnace temperature should be raised as much as possible on the premise that slag is not formed in the furnace.
The temperature of flue gas generated by a biomass-fired boiler is relatively high. But it is not corrosive. So, it is suitable to use heat resisting glass fiber needled felt bag which has a good use effect. Moreover, this kind of cloth bag is not very expensive.
Boiler controls provide an extra level of safety and reassurance: they allow you to understand your boiler's daily operations better, as well as perform the crucial duty of ensuring that your boiler is operating safely and efficiently. Regardless of what kind of industrial or commercial operation you run, here are some must-have boiler controls to get the most out of your equipment.
Question details (Performance):The steam pipe vibrates violently and has a dull impact sound.Answer: fault reason: There is air in pipeline ; automatic air vent valve is not turned on; or it is out of order. Troubleshooting: Check all the air release valves on the water supply pipe and the air release valves on the top of the boiler tube for gas storage. If the valve fails, it should be replaced immediately.
Question details (Performance):1. The furnace wall at the coal economizer leaks water and steam with abnormal sound.2. The water level in the boiler drops sharply, and the water supply is obviously greater than the evaporation capacity.3. Smoke exhaust temperature and water outlet temperature rise.Answer: Fault reason:1. The water quality does not reach standard, and the oxygen in the water is decomposed into corroded pipe walls when the temperature rises.2. The low feed water temperature and smoke exhaust temperature make the inner and outer wall of the coal economizer pipe produce acid corrosion, or flying ash wear the pipe wall thin. 3. The pipe is blocked by impurities, causing overheating.4. Poor materials, defects in manufacturing, installation and maintenance. Troubleshooting:1. When economizer is slightly broke, it still maintains boiler operation, and the gap seems will not expand rapidly, in this case, load operation should be reduced, and start the spare boiler immediately,