The action of starting up a fire tube boiler for the first time is already a cold start. As a result, the mechanical load in this type of boiler is much greater, as the main characteristic of cold starts is the absence of boiling water and greater stress on the connection and anchorage elements of the boiler.
To make this start a bit easier for the boiler, the boiler operator should reduce the burner load to a boiling point.
Industrial boilers are machines or engineering devices whose primary objective is the generation of steam. The heat that is generated, which can come from any energy source, causes it to be transformed into energy for use, either through a liquid phase medium or steam.
A biomass boiler is a boiler designed to burn solid fuels classed as biomass. Such boilers can be supplied to burn every form of biomass from woodchips, wood pellets or logs to waste agricultural materials such as straw and grain husks, olive kernels, rice and the dust from any of these including sawdust. Boilers need to be designed to burn specific materials, with any given boiler able to burn a limited range of biomass.
ZOZEN biomass-fired boiler has wide fuel adaptability, is suitable for a wide variety of biomass fuels including biomass particle, wood chips, palm shell, straw and so on. The engineering technique personnel of ZOZEN optimized the design of the feeding hopper, the length and width of the fire grate, rotary speed of gearbox, 1st and 2nd air ratio, vapor orientation and position, etc; the above upgrades ensure the high thermal efficiency and stable operation of the boiler.
Question details (Specific performance):Biomass environmental protection and energy saving fuel made of straw and livestock etc., their combustion is not full. Answer: The cause of the problem:1. Air quantity is insufficient or too big.2. Outer flame position is not proper.Troubleshooting:1.Sufficient temperature: sufficient combustion of biomass boiler needs high temperature, combustion rate is proportional to the temperature, to raise the temperature as much as possible but guarantee there is no slagging.2. Proper air volume. If the air volume is too large, it will reduce the temperature of the furnace and increase the incomplete combustion of fuel. If the air volume is insufficient, the combustion efficiency will be reduced, and the waste of fuel will also increase the emission of smoke.3. Sufficient mixing of fuel and air. During the burning stage of biomass boilers, the sufficient mixing of air and fuel should be ensured and the disturbance should be strengthened during the burnin
(Question Details) Specific Performance:(1) The bed temperature has risen sharply.(2) The oxygen level drops even to zero.(3) The current of the primary blower is reduced, and the wind pressure in the wind chamber is high and fluctuates.(4) The furnace negative pressure increases and the induced draft fan current decreases.(5) Difficulties in slagging.(6) If coking in low temperature, the bed temperature, bed pressure distribution is uneven, the deviation is too large, the bed pressure, the plenum pressure, the bed temperature is not normal, and the local bed temperature measurement point is not normally raised or lowered.(7) The bed pressure indicator value fluctuates little. Answer: causes of failure :(1) Improper operation, resulting in overheated bed temperature and coking.(2) The primary air volume during operation is kept too small, which is lower than the minimum fluidized air volume, so that the material can’t be well fluidized but piled up, the temperature field of the entire