In the whole drying process, we should pay attention to gradually increasing the temperature instead of burning by raging fire; regularly checking boiler's water level and keeping it within the normal range; keeping the flame balanced in the furnace. In addition, we also should properly open the drainage valve and maintain the water level, regularly record the flue gas temperature to control the rise of temperature and high temperature and keep the temperature within the normal range. In general, under these conditions, boiler’s drying quality can be ensured.
The thermal efficiency of an industrial boiler is a measure of how effectively the boiler converts the energy contained in the fuel into usable heat. It is typically expressed as a percentage, indicating the ratio of heat output for heating or producing steam to the energy input from the fuel consumed. This efficiency is crucial for understanding the performance of a boiler, as it directly impacts fuel consumption, operational costs, and environmental emissions.
Factors Influencing Thermal Effi...
A hybrid or combination boiler system refers to a heating system that combines two different types of heating technologies or fuels to optimize efficiency, performance, and cost-effectiveness. This system typically involves the integration of a traditional gas or oil boiler with a renewable energy source, such as a solar thermal system, a biomass boiler, or a heat pump. The idea is to harness the strengths of both systems to achieve greater energy efficiency and environmental sustainability.
Ke...
If the burner motor of a gas-fired boiler is running and voltage is present at the controller terminal, but there is no ignition followed by a system failure and stop, this situation can be attributed to several potential issues. Here's a breakdown of what might be happening and what to check:
Ignition System Failure: The ignition system, which may include spark electrodes or an igniter, could be faulty. Check for any signs of damage, misalignment, or dirt on the igniter or electrodes.
Control...
First of all, don't panic. According to the normal shutdown sequence, check whether the fuel, steam and water valves of gas-fired boiler meet the shutdown requirements.
Secondly, close the surface blowdown valve of the gas-fired boiler to prevent other faults of the boiler. Then, quickly close the main steam valve to prevent the gas boiler drum from losing water.
Thirdly, close the deaerator air supply valve, the main power switch and the natural gas valve. The air inlet of the gas-fired boiler burner should not be blocked to reduce the area of the air inlet, and the room ventilation should not be blocked to avoid the formation of toxic and harmful gases.
Generally, it is required that the water temperature shall be reduced to 80℃ to drain the water in the boiler. This is because if the water temperature is high, the temperature in the furnace is still very high, and the metal of the furnace wall and heating surface will still accumulate some heat. After the water is released, there is no working medium in the water wall to cool, which makes the wall temperature rise and the temperature rise is uneven, which is not conducive to the safety of the water wall.
The limited space refers to a space which is closed or partially closed, relatively isolated from the outside world, with narrow entrances and exits, staff can't work in it for a long time, natural ventilation is poor, and toxic, harmful, inflammable and explosive substances or oxygen content is easy to accumulate. To define a limited space, it is necessary to meet the following three conditions at the same time, which are indispensable: the volume is large enough for people to enter completely; Or restrict the entry and exit; It's not designed to stay for a long time.
The advantages of boiler fueled by the methanol can be concluded as follows:
a. The emission from boiler fueled by the methanol is very environmentally friendly, without sulfur, particulate matter, heavy metals and polycyclic aromatic hydrocarbons.
b. The methanol fuel is quite cost-effective.
c. The operation of boiler fueled by the methanol is safety. Compared with compressed natural gas, liquefied petroleum gas, gasoline and diesel fuel, methanol has the char...