zozen boiler
HomeBoiler tagsdifference between water tube boiler and fire tube boiler

“difference between water tube boiler and fire tube boiler”- related faq

  • What are the biomass pellets for a biomass-fired boiler? 2020-04-24
    Biomass fuel can be applied to a biomass-fired boiler by treatment and compression molding. Commonly used are straw particles, rice husk particles, wood particles, sawdust particles, peanut rod particles, sugar aldehyde residue particles, palm shell particles and so on.
  • What are the characteristics of gas-fired boilers? 2020-04-24
    1. The control system is equipped with a special computer controller, which makes the boiler running clear and easy to operate. 2. The burner is controlled by full-automatic program, and in case of failure, the burner stops automatically. 3. The boiler body is designed with reasonable structure, and the top is equipped with air vent. The boiler works under normal pressure and is far away from explosion danger. The full wet back three-way structure and corrugated tank design are adopted. The flue gas process is long, the temperature of exhaust gas is reduced, the heat transfer coefficient is increased, and the equipment life is prevented from being reduced due to the expansion and contraction of metal.
  • What is the working principle of the oil-gas separator of a thermal oil heater? 2020-04-17
    Generally, there is moisture in heat medium oil. And, the moisture will be evaporated during the heating process of the oil. If the water vapor is not discharged from the thermal oil heater, it will cause the fluctuation of heat medium oil pressure. However, the oil-gas separator can separate the water vapor from the heat medium oil and discharge it from the heater, which ensures the stable oil pressure.
  • How to deal with the sudden stop of the  circulating pump of a thermal oil heater? 2020-04-17
    If the circulating pump of a thermal oil heater stops working suddenly. Then, some measures should be taken immediately to remove the fire source. If not, the stop of circulating pump will cause coking in the oil tube, which will shorten the service life of the heater.
  • What is the calculation method of the circulating water volume of a coal-fired hot water boiler? 2020-04-10
    The coal-fired boiler refers to the boiler uses various types of coal as fuel and converts the heat of coal to steam or hot water. There are generally two calculation methods of the circulating water volume of a coal-fired hot water boiler. One is to calculate the hourly water volume of one square meter and the other is to calculate the design parameter volume of every ton. As for the make-up water volume of this type of boiler, it is usually calculated as 1% to 3% of its total circulating water.
  • What is a nonsteaming economizer? 2020-04-10
    If the final temperature of feed water doesn’t reach the saturated temperature after being heated by an economizer, (that is, the feed water has not reached the boiling state), we call the economizer as a nonsteaming economizer. Generally, the final temperature is 30-50℃ lower than the saturated temperature.
  • How is the dry bottom hopper formed in an industrial boiler? 2020-04-10
    The dry bottom hopper is formed by bending the lower part of the water wall of the front and rear walls inward. The main function is to gather, cool and automatically discharge ash. It is also convenient for the connection and sealing of the lower header and the ash well.
  • What is the oil ignition point of industrial boilers? 2020-04-03
    When the oil temperature rises to a certain temperature that the oil and gas molecules on the surface of the oil tend to saturate, can catch fire and maintain continuous combustion for a duration of not less than 5S. The temperature is called ignition point.
1...22 23 24 25 26 27 28 29...35