zozen boiler
HomeBoiler tagsdifference between water tube boiler and fire tube boiler

“difference between water tube boiler and fire tube boiler”- related faq

  • How is the dry bottom hopper formed in an industrial boiler? 2020-04-10
    The dry bottom hopper is formed by bending the lower part of the water wall of the front and rear walls inward. The main function is to gather, cool and automatically discharge ash. It is also convenient for the connection and sealing of the lower header and the ash well.
  • What is the oil ignition point of industrial boilers? 2020-04-03
    When the oil temperature rises to a certain temperature that the oil and gas molecules on the surface of the oil tend to saturate, can catch fire and maintain continuous combustion for a duration of not less than 5S. The temperature is called ignition point.
  • What is the reason for the failure of the draft fan of the biomass-fired boiler? 2020-04-03
    Four factors are related to the failure of the draft fan of the biomass-fired boiler. The factors are electric, electrical motors, dampers and induced draft fans. Therefore, if the draft fan breaks down, you can check the electric and electrical motor first, then you can check the damper and the induced fan.
  • Does the biomass-fired boiler need to be shut down for maintenance? 2020-04-03
    Biomass-fired boilers need to be shut down for maintenance. Proper maintenance can reduce the damage to the boiler caused by continuous work. Firstly, it is necessary to cut off all power to prevent being struck by lightning. In addition, dust, limescale and carbon deposits should be cleaned up to prevent rust and corrosion of the boiler.
  • What is the function of the storage tank of a thermal oil heater? 2020-03-27
    1. The storage tank is used to store the heat medium oil of the heating system; 2. The storage tank is used to receive the overrunning heat medium oil; 3. The storage tank is used to supplement heat medium oil for the heating system; 4. The storage tank should be placed at the lowest position of the system; 5. A firewall should be placed between the storage tank and the thermal oil heater; 6. The storage tank should be operated at a low liquid level.
  • How to select a burner for the gas-fired thermal oil heater? 2020-03-20
    The selection of a burner of the gas-fired thermal oil heater should be determined according to the boiler proper structure and fuel characteristics and in combination with the actual conditions and requirements. In addition, this kind of boiler can adopt a waste heat recovery device to improve thermal efficiency and reduce heat energy loss.
  • What is the theoretical daily coal consumption of a set of 20 tph coal-fired chain grate steam boiler 2020-03-13
    Coal-fired boilers refer to boilers that use various kinds of coals as fuel and convert the heat value of coals to steam or hot water. Some specific parameters should be provided to calculate the theoretical coal consumption of a set of 20 tph coal-fired boiler. If the rated steam pressure is 1 MPa, the heat value of coal is 7000 kcal / kg, the boiler inlet water temperature is 20 ° C, and the boiler thermal efficiency is 80%, the daily coal consumption is 50-56 tons.
  • What are the maintenance contents of main systems of a gas-fired boiler? 2020-03-06
    Maintenance of the burner: thoroughly clean the rotor plate, ignition device, filter, oil pump, motor and impeller system, and add lubricant to the connecting rod device of air valve. Retest the combustion condition.