The natural gas testing of the boiler is to measure various thermal performance parameters of the boiler in a stable working condition (that is, in a normal combustion state), so as to judge the energy efficiency of the boiler. Natural gas testing can determine the thermal efficiency of the boiler, determine the size of each heat loss of the boiler, analyze the causes of each heat loss and seek ways to reduce the heat loss, so as to improve the energy efficiency of the boiler. What is the testin...
Natural gas boiler heating is an important livelihood project, and the design of natural gas boiler heating is related to whether the heating is safe, stable, efficient and environmentally friendly. As a professional supplier of natural gas boilers, ZOZEN Boiler has summarized a heating design solution for natural gas boilers.
The working principle of natural gas boiler heating is that the circulating water is transported to the boiler inlet by the circulating water pump, and after bein...
Before coking and boiling, check boiler parts detailedly. Inspection items are as follows:
1. Before coking and boiling, chain grate should be cold test run again and continuous running time shall not be less than 24 hours.
2. Ignition door can be opened flexibly, coal gate can be lift and dropped conveniently, coal gate left and right side is of the same distance to grate, and ensure the material layer thickness on both sides of the furnace is equal. If distance is not equal, it can be adjust...
1. After boiler body, economizer, air pre-heater, dust collector, etc are in place and installed, connect FD fan, ID fan, etc according to drawing and then connect corresponding flue gas duct. After fan in place, alignment between foundation and equipment base should be conducted with parallels. Fan position alignment should center on a shaft, central elevation deviation and vertical and lateral central line positional deviation should be 10mm or less and fan spindle should be in level state. Th...
1. Burner should be installed in accordance with requirements of burner installation and operation manual.
2. Burner should be installed in the center of the reserved front wall hole, the embeded length should comply with the design requirements and the fixation should be reliable.
3. Burner center deviation shall not be more than +2mm and air adjustment actuator should be flexible.
4. Burner and boiler body junction surface should be sealed reliably, the position that needed to be sealed bet...
The design and construction of gas boiler room is also a very important point in boiler safety. How to install the gas boiler should also conform to the boiler room design specification, and it is necessary to comply with the site, space, protection and other aspects.
How to install the gas boiler?
How to install the gas boiler is mainly based on the Boiler Room Design Code and Boiler Safety Technical Inspection Code. In addition, the Urban Gas Design Code and the Fire Protection Code ...
Industry boiler is an important thermal power device, which is widely used in factory power, building heating, people's life and other aspects, with a large demand and a wide variety. According to the different flue gas passes, gas-fired boilers are divided into two-pass and three-pass boiler structures. Here, ZOZEN Boiler focuses on the structure and process principle of the common three-pass boiler.
The first pass: after the fuel is atomized by the burner, the formed torch is filled i...
When the boiler flue gas is saturated wet flue gas, the flue gas contains a large amount of water vapor. At this time, if the flue gas is directly discharged from the chimney and enters the low-temperature ambient air, and the saturated humidity of the ambient air is relatively low, the water vapor in the flue gas will condense to form wet plumes, which is often called "white smoke".
The water in the flue gas of the boiler is produced during the combustion of the hydrogen element of hyd...