Ash accumulation on the heating surface.
The scaling and ash deposition on the water-cooled wall of the furnace and the ash deposition of the superheater, convention tube bundles, economizer and preheater can increase the thermal resistance of the flue gas, weaken the heat transfer, lessen the cooling effect of the flue gas and increase the exhaust gas temperature of the gas-fired boiler.
Too high excess air coefficient.
Under normal circumstances, as the furnace outlet excess...
A condensing boiler can condense the water vapour in the flue gases and withstand the corrosive and acidic qualities of the flue gas condensate. Although most boilers can condense the flue gasses, only boilers that have heat exchangers constructed from materials able to withstand the corrosion should be used in condensing application. Condensing boilers with primary and secondary heat exchanger do not work well as they are not able to fully condense and defeat the purpose of using a condensing boiler. Also, boilers with this arrangement are prone to condensation in the primary heat exchanger at lower firing rate which can cause damage to the heat exchanger.
Gas-fired hot water boilers require high-quality water to improve the boiler performance and extend the service life. If the boiler uses the tap water of water which contains a lot of impurities, magnesium and calcium ions in the water will form white precipitates when the water is heated at high temperatures, which can cause the scaling problem to reduce the heat transfer efficiency of the boiler and bring hidden dangers of the boiler safety.
1. During the start-up process of the burner, if the burner repeatedly alarms and locks, it should be found out the reason, find the fault and eliminate it, and then press the reset button to inherit the start. Note: The continuous press of the reset button should not exceed 10 seconds
2. If the burner is not successful in one combustion, the natural gas boiler induced draft fan should be restarted, and the second combustion can be started after 5 minutes of ventilation.
3. In the normal operation era, the burner close to the thermal equipment department (such as the connecting flange, etc.) will be very hot, to prevent the formation of burns. Do not place flammable materials in the vicinity to avoid causing fire.
4. During the operation of natural gas-fired boilers, it is necessary to closely supervise the working conditions of hot water circulation pumps and natural gas-fired boiler pressures, natural gas distribution bags, pipeline valves, pressure gauges, flow meters, and water
The fuel of a gas-fired boiler is gas such as natural gas, city gas, biogas and liquefied gas, etc. What kind of fuel the boiler burns is decided by an equipment called a burner. The boiler equipped with a gas-fired burner is called a gas-fired boiler. There are three methods of gas-fired boiler combustion as per technical characteristics of how the gas and air mix.
1. Diffusion combustion:
Gas and air mutually diffuse at the gas nozzle and are burning. The advantages are burning stably and with simple burner structure. However, the heated area is easy to be carbonized due to long flame, which is easy to produce incomplete combustion.
2. Premixed combustion:
A part of air and gas are premixed before combustion (coefficient of primary air surplus is between 0.2-0.8), and then being burned. The advantages are clear combustion flame, enhanced combustion, and high thermal efficiency.
The explosion-proof door of the gas-fired boiler is opened or broken when the combustible gas explosion suddenly increases the pressure, it then releases high-pressure gas to reduce the damage to the gas-fired boiler body and also ensure
The function of the gas-fired boiler explosion-proof door is usually reflected when the gas-fired boiler is ignited or running due to improper operation. For instance, the furnace is not purged before ignition, the furnace is still not purged even the ignition cannot successfully be lit, the nozzle is leaking, the fuel is not completely burned, and extinguished failure to cut off fuel quickly, etc. all of them may cause the furnace and tail flue to explode. Installing explosion-proof door for gas-fired boiler is to release the pressure to avoid the accident from expanding and also to ensure the safety of the industrial steam boiler when a slight explosion occurs in the furnace or flue.
The combustion air will be heated to the flame temperature. This heating cost money. If you have some waste heat to be used for preheating the combustion air it will pay.
The thermal oil heater is a heater that uses heat medium oil as medium for heat transfer. The low-pressure and high-temperature heating can be realized by the utilization of the high-temperature characteristics of heat medium oil.If there is too much moisture in the low-temperature heat medium oil, there will be pressure fluctuations, which will cause some other problems. In addition, if the heat medium oil does not flow in the furnace owing to the stop of pump, the oil temperature will rise and exceed the limit value, which not will greatly affect the service life of the heater and cause the deterioration of the heat medium oil.