Why gas-fired hot water boilers require the softened water?
Gas-fired hot water boilers require high-quality water to improve the boiler performance and extend the service life. If the boiler uses the tap water of water which contains a lot of impurities, magnesium and calcium ions in the water will form white precipitates when the water is heated at high temperatures, which can cause the scaling problem to reduce the heat transfer efficiency of the boiler and bring hidden dangers of the boiler safety. To be specific,
1) The heating tube has scaling loss due to overheat and the scale has poor thermal conductivity. Too much scale on the heating tube will cause the internal temperature of the heating tube to be unable to diffuse, which will cause the cracking of outer tube.
2) The thicker the scale, the higher the fuel consumption, which will reduce the heat transfer efficiency of the heating tube and lengthen the heating time.
3) If the steam pressure of the boiler reduces, the heat will not be transferred to the boiler water quickly, and the output pressure of the equipment will not meet the requirements for use.
4) It will be very difficult to remove the scale on the internal wall of the boiler and the heating tube. The scale can cause the cracking and corrosion of the heating tube or boiler body, which will not only damage the equipment, but also will increase the inspection and maintenance costs.
5) The scale needs to be cleaned with chemical agents. To much clean will damage the boiler, reduce the service life of the boiler, and increase the hidden dangers of boiler safety.
-
WNS series gas-fired (oil-fired) hot water boilerLive Chat0.7-14 MW0.7-1.25 MPa
-
SZS series gas-fired (oil-fired) hot water boilerLive Chat7-116 MW1-1.6 MPa
-
WNS series gas-fired (oil-fired) steam boilerLive Chat1-20 t/h0.7-2 MPa
-
Email us
-
WhatsApp: +86 18861589035
WeChat: +86 13506150756
Live Chat
-
Recently, ZOZEN Boiler successfully delivered a DZW series 20-ton reciprocating grate biomass steam boiler to Kohinoor Mills, a renowned textile enterprise in Pakistan, supporting its transition to green and sustainable production. This collaboration not only underscores ZOZEN’s growing influence in overseas markets, but also highlights its technological innovation and professional service capabilities in the biomass boiler field. ZOZEN Biomass Boiler Supports Pakistan’s T...26 Aug 2025
-
In the global leisure and entertainment product manufacturing sector, Bestway Group is undoubtedly a leading player. With operations spanning over 200 countries and regions, its product portfolio covers around 800 items across leisure, sports, and camping categories. As the company continues to expand its industrial footprint, the Bestway plant in Tien Giang Province, Vietnam, faced an urgent need for a reliable and efficient heat energy supply to support production. ZOZEN Provides a Tailored...19 Aug 2025
-
In 1886, Atlanta pharmacist John Pemberton mixed the first glass of Coca-Cola. What began as a “brown tonic” selling 25 bottles a day has since become a global beverage legend, spanning more than 200 countries with 2 billion servings consumed daily. In Mongolia, its exclusively authorized producer MCS Coca-Cola is expanding into new categories such as iced tea and juices. Powering this strategy is the thermal engine behind the scenes: three 8 t/h WNS series gas-fired steam boilers fr...12 Aug 2025